1.1 This specification covers minimum-wall-thickness, electric-resistance-welded, carbon steel tubes to be used for heat exchangers, condensers, and similar heat-transfer apparatus.
1.2 The tubing sizes usually furnished to this specification are to 3 in. [76.2 mm] in outside diameter, inclusive. Tubing having other dimensions may be furnished, provided such tubes comply with all other requirements of this specification.
1.3 Mechanical property requirements do not apply to tubing smaller than 1/8 in. [3.2 mm] in inside diameter or 0.015 in. [0.4 mm] in thickness.
1.4 The purchaser shall specify in the order the outside diameter and minimum wall thickness. The inside diameter shall not be specified.
1.5 The values stated in either inch-pound units or SI units are to be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each system are not exact equivalents; therefore, each system must be used independently of the other. Combining values from the two systems may result in nonconformance with the specification. The inch-pound units shall apply unless the "M" designation of this specification is specified in the order.
Standard Test Methods for Moisture in Textiles
$28.00 $57.00
Standard Test Method for Determination of Cannabinoids in Cannabis Raw Materials and Resin Cannabis Products by Gas Chromatography and Flame Ionization Detection
Standard Test Methods for Sulfur Dioxide Content of the Atmosphere (West-Gaeke Method)
$30.00 $60.00
Standard Test Method for Wind Resistance of Concrete and Clay Roof Tiles (Air Permeability Method)
$24.00 $48.00