1.1 This test method covers procedures for testing concrete pipe sewerlines, when using the negative air pressure (vacuum) test method to demonstrate the integrity of the installed material and the construction procedures. This test method covers testing of 4 to 36-in. diameter circular concrete pipe sewerlines utilizing gasketed joints.

Note 1 - The user of this test method is advised that methods described herein may also be used as a preliminary test to enable the manufacturer or installer to demonstrate the condition of sewer pipe prior to delivery or backfill. Minimum test times presented in Table 1 are for pipelines. Holding times for testing an individual pipe may have to be increased to allow for the accumulation of leakage when the tested pipe are incorporated into a continuous pipeline.

Note 2 - The user of this test method is advised that the negative air pressure (vacuum) test criteria presented in this test method are similar to those in general use. The test and criteria have been used widely and successfully in testing smaller diameter pipe. Larger pipe will be accepted more conveniently by visual inspection and individual joint testing.

Note 3 - The user of this test method is advised that no correlation has been found between loss of vacuum and water leakage.

1.2 This test method is the inch-pound companion to Test Method C 1214M; therefore, no SI equivalents are presented in the test method.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. See Section 6 for specific safety precautions.

TABLE 1 Minimum Test Time

Nominal
Pipe
Size, in.
T (Time),
min/100 ft
Nominal
Pipe
Size, in.
T (Time),
min/100 ft
4 0.3 21 3.0
6 0.7 24 3.6
8 1.2 27 4.2
10 1.5 30 4.8
12 1.8 33 5.4
15 2.1 36 6.0
18 2.4

More ASTM standard pdf

ASTM F567-14

ASTM F567-14

Standard Practice for Installation of Chain-Link Fence

$25.00 $50.00

ASTM D7773-19

ASTM D7773-19

Standard Test Method for Determination of Volatile Inorganic Acids (HCl, HBr, and HNO 3) Using Filter Sampling and Suppressed Ion Chromatography

$25.00 $50.00

ASTM D852-16

ASTM D852-16

Standard Test Method for Solidification Point of Benzene

$27.00 $54.00

ASTM F2336-05

ASTM F2336-05

Standard Guide for Roller Hockey Playing Facilities (Withdrawn 2014)

$25.00 $50.00