Standard Practice for Reporting Uniaxial Strength Data and Estimating Weibull Distribution Parameters for Advanced Ceramics

ASTM International, 02/01/2007

Publisher: ASTM

File Format: PDF

$33.00$67.00


Published:01/02/2007

Pages:19

File Size:1 file , 340 KB

Note:This product is unavailable in Russia, Ukraine, Belarus

1.1 This practice covers the evaluation and reporting of uniaxial strength data and the estimation of Weibull probability distribution parameters for advanced ceramics that fail in a brittle fashion (see Fig. 1). The estimated Weibull distribution parameters are used for statistical comparison of the relative quality of two or more test data sets and for the prediction of the probability of failure (or, alternatively, the fracture strength) for a structure of interest. In addition, this practice encourages the integration of mechanical property data and fractographic analysis.

1.2 The failure strength of advanced ceramics is treated as a continuous random variable determined by the flaw population. Typically, a number of test specimens with well-defined geometry are failed under isothermal, well-defined displacement and/or force-application conditions. The force at which each test specimen fails is recorded. The resulting failure stress data are used to obtain Weibull parameter estimates associated with the underlying flaw population distribution.

1.3 This practice is restricted to the assumption that the distribution underlying the failure strengths is the two-parameter Weibull distribution with size scaling. Furthermore, this practice is restricted to test specimens (tensile, flexural, pressurized ring, etc.) that are primarily subjected to uniaxial stress states. The practice also assumes that the flaw population is stable with time and that no slow crack growth is occurring.

1.4 The practice outlines methods to correct for bias errors in the estimated Weibull parameters and to calculate confidence bounds on those estimates from data sets where all failures originate from a single flaw population (that is, a single failure mode). In samples where failures originate from multiple independent flaw populations (for example, competing failure modes), the methods outlined in Section 9 for bias correction and confidence bounds are not applicable.

1.5 This practice includes the following:

1.6 The values stated in SI units are to be regarded as the standard per IEEE/ASTM SI 10.

More ASTM standard pdf

ASTM B535-04

ASTM B535-04

Standard Specification for Nickel-Iron-Chromium-Silicon Alloys (UNS N08330 and N08332) Seamless Pipe and Tube

$26.00 $52.00

ASTM F1444-00(2004)

ASTM F1444-00(2004)

Standard Test Method for Determining Dynamic Thermal Response of Direct Thermal Paper-Label Printer Method

$25.00 $50.00

ASTM D1566-04

ASTM D1566-04

Standard Terminology Relating to Rubber

$33.00 $67.00

ASTM C496/C496M-11

ASTM C496/C496M-11

Standard Test Method for Splitting Tensile Strength of Cylindrical Concrete Specimens

$30.00 $60.00