1.1 This test method covers the determination of transthickness tensile strength (S U T) under monotonic uniaxial loading of continuous fiber-reinforced ceramics (CFCC) at ambient temperature. This test method addresses, but is not restricted to, various suggested test specimen geometries, test fixtures, data collection and reporting procedure. In general, round or square test specimens are tensile tested in the direction normal to the thickness by bonding appropriate hardware to the samples and performing the test. For a Cartesian coordinate system, the x-axis and the y-axis are in the plane of the test specimen. The transthickness direction is normal to the plane and is labeled the z-axis for this test method. For CFCCs, the plane of the test specimen normally contains the larger of the three dimensions and is parallel to the fiber layers for uni-directional, bi-directional, and woven composites. Note that transthickness tensile strength as used in this test method refers to the tensile strength obtained under monotonic uniaxial loading where monotonic refers to a continuous nonstop test rate with no reversals from test initiation to final fracture.

1.2 This test method is intended primarily for use with all advanced ceramic matrix composites with continuous fiber reinforcement: unidirectional (1-D), bidirectional (2-D), woven, and tridirectional (3-D). In addition, this test method also may be used with glass (amorphous) matrix composites with 1-D, 2-D, and 3-D continuous fiber reinforcement. This test method does not address directly discontinuous fiber-reinforced, whisker-reinforced or particulate-reinforced ceramics, although the test methods detailed here may be equally applicable to these composites. It should be noted that 3-D architectures with a high volume fraction of fibers in the " z" direction may be difficult to test successfully.

1.3 Values are in accordance with the International System of Units (SI) and Practice E380.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Additional recommendations are provided in and Section .

More ASTM standard pdf

ASTM E2907/E2907M-13

ASTM E2907/E2907M-13

Standard Practice for Examination of Paper Machine Rolls Using Acoustic Emission from Crack Face Rubbing

$29.00 $58.00

ASTM E1849-96

ASTM E1849-96

Standard Guide for Fish and Wildlife Incident Monitoring and Reporting

$41.00 $83.00

ASTM E1847-96

ASTM E1847-96

Standard Practice for Statistical Analysis of Toxicity Tests Conducted Under ASTM Guidelines

$31.00 $62.00

ASTM D6037-13e1

ASTM D6037-13e1

Standard Test Methods for Dry Abrasion Mar Resistance of High Gloss Coatings

$30.00 $60.00