Your shopping cart is empty!
ASTM International, 02/01/2022
Publisher: ASTM
File Format: PDF
$24.00$48.00
Published:01/02/2022
Pages:4
File Size:1 file , 79 KB
Note:This product is unavailable in Russia, Ukraine, Belarus
1.1''This test method covers the determination of particle size distribution of advanced ceramic powders. Experience has shown that this test method is satisfactory for the analysis of silicon carbide, silicon nitride, and zirconium oxide in the size range of 0.1 up to 50 ''m.
1.1.1''However, the relationship between size and sedimentation velocity used in this test method assumes that particles sediment within the laminar flow regime. It is generally accepted that particles sedimenting with a Reynolds number of 0.3 or less will do so under conditions of laminar flow with negligible error. Particle size distribution analysis for particles settling with a larger Reynolds number may be incorrect due to turbulent flow. Some materials covered by this test method may settle in water with a Reynolds number greater than 0.3 if large particles are present. The user of this test method should calculate the Reynolds number of the largest particle expected to be present in order to judge the quality of obtained results. Reynolds number (Re) can be calculated using the following equation:
1.1.2''A table of the largest particles that can be analyzed with a suggested maximum Reynolds number of 0.3 or less in water at 35'''''C is given for a number of materials in Table 1. A column of the Reynolds number calculated for a 50-''m particle sedimenting in the same liquid system is also given for each material. Larger particles can be analyzed in dispersing media with viscosities greater than that for water. Aqueous solutions of glycerine or sucrose have such higher viscosities.
1.2''The procedure described in this test method may be applied successfully to other ceramic powders in this general size range, provided that appropriate dispersion procedures are developed. It is the responsibility of the user to determine the applicability of this test method to other materials. Note however that some ceramics, such as boron carbide and boron nitride, may not absorb X-rays sufficiently to be characterized by this analysis method.
1.3''The values stated in cgs units are to be regarded as the standard, which is the long-standing industry practice. The values given in parentheses are for information only.
1.4''This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific hazard information is given in Section 8.
1.5''This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Standard Test Method for Performance of Underfired Broilers
$32.00 $65.00
Standard Test Method for Measuring Electrical Energy Requirements of Processing Equipment (Withdrawn 2014)
$29.00 $58.00
Standard Guide for Consensus-based Process for an Occupational Safety and Health Standard that Includes an Occupational Exposure Guideline
$27.00 $54.00
Standard Test Methods for Determination of Gold in Bullion by Fire Assay Cupellation Analysis
$24.00 $48.00