Your shopping cart is empty!
ASTM International, 04/01/2009
Publisher: ASTM
File Format: PDF
$30.00$60.00
Published:01/04/2009
Pages:7
File Size:1 file , 370 KB
Note:This product is unavailable in Russia, Ukraine, Belarus
1.1 This test method covers the estimation of the electrical corrosion potential of uncoated reinforcing steel in field and laboratory concrete, for the purpose of determining the corrosion activity of the reinforcing steel.
1.2 This test method is limited by electrical circuitry. Concrete surface in building interiors and desert environments lose sufficient moisture so that the concrete resistivity becomes so high that special testing techniques not covered in this test method may be required (see 5.1.4.1). Concrete surfaces that are coated or treated with sealers may not provide an acceptable electrical circuit. The basic configuration of the electrical circuit is shown in Fig. 1.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
FIG. 1 Reference Electrode Circuitry
Standard Practice for Describing and Specifying a Wavelength-Dispersive X-Ray Spectrometer
$29.00 $58.00
Standard Practice for Preparation of Samples of the Constant Composition Region of Epitaxial Gallium Arsenide Phosphide for Hall Effect Measurements
$25.00 $50.00
Standard Test Method for Measuring the Interzone Attenuation of Ceiling Systems
Standard Practices for Simulated Service Testing for Corrosion of Metallic Containment Materials for Use With Heat-Transfer Fluids in Solar Heating and Cooling Systems