• ASTM D3359-08

ASTM D3359-08

Standard Test Methods for Measuring Adhesion by Tape Test

ASTM International, 02/01/2008

Publisher: ASTM

File Format: PDF

$30.00$60.00


Published:01/02/2008

Pages:7

File Size:1 file , 130 KB

Note:This product is unavailable in Russia, Ukraine, Belarus

1.1 These test methods cover procedures for assessing the adhesion of coating films to metallic substrates by applying and removing pressure-sensitive tape over cuts made in the film.

Note 1 - This test method has been reported being used to measure adhesion of organic coatings on soft substrates (for example, wood and plastic). Issues with plastic substrates are noted in Appendix X1. A similar test method, ISO 2409, permits tests on soft substrates (for example, wood and plaster). Precision and bias data on the later is lacking. Test Methods D 3359 was developed with metal as the substrate and, in the absense of supporting precision and bias data, is so limited.

1.2 Test Method A is primarily intended for use at job sites while Test Method B is more suitable for use in the laboratory. Also, Test Method B is not considered suitable for films thicker than 5 mils (125μm).

Note 2 - Subject to agreement between the purchaser and the seller, Test Method B can be used for thicker films if wider spaced cuts are employed.

1.3 These test methods are used to establish whether the adhesion of a coating to a substrate is at a generally adequate level. They do not distinguish between higher levels of adhesion for which more sophisticated methods of measurement are required.

Note 3 - It should be recognized that differences in adherability of the coating surface can affect the results obtained with coatings having the same inherent adhesion.

1.4 This test method is similar in content (but not technically equivalent) to ISO 2409.

1.5 In multicoat systems adhesion failure may occur between coats so that the adhesion of the coating system to the substrate is not determined.

1.6 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.7 This standard does not purport to address the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

More ASTM standard pdf

ASTM E2749-15a(2019)

ASTM E2749-15a(2019)

Standard Practice for Measuring the Uniformity of Furnace Exposure on Test Specimens

$37.00 $75.00

ASTM C1367-19

ASTM C1367-19

Standard Test Method for Dead Load Resistance of a Sealant in Elevated Temperatures

$30.00 $60.00

ASTM D8278-19

ASTM D8278-19

Standard Specification for Digital Contact Thermometers for Test Methods Measuring Flow Properties of Fuels and Lubricants

$27.00 $54.00

ASTM E34-11

ASTM E34-11

Standard Test Methods for Chemical Analysis of Aluminum and Aluminum-Base Alloys

$43.00 $86.00