• ASTM D3752-98(2002)e1

ASTM D3752-98(2002)e1

Standard Test Method for Strength Imparted by Asbestos to a Cementitious Matrix

ASTM International, 08/10/1998

Publisher: ASTM

File Format: PDF

$30.00$60.00


Published:10/08/1998

Pages:7

File Size:1 file , 120 KB

Note:This product is unavailable in Russia, Ukraine, Belarus

1.1 This test method covers the measurement, on a laboratory scale, of the contribution of asbestos fibers to the strength of asbestos-cement products. The results obtained are used in the primary assessment of different fiber grades prior to their application on a larger scale.

1.2 This test method covers the determination of the modulus of rupture (MR), adjusted to a dry density of 1.60 Mg/m³ (MR A ), of asbestos-cement test specimens that contain the asbestos fiber to be evaluated at a concentration of 10 mass %, whereby the degree of fiberization of that fiber is specified in terms of specific surface area as determined by Test Method D 2752. The relative reinforcing value of the fiber under test is established by comparison with MR A values obtained with a fiber of known characteristics at a fiber concentration of 10 % and a dry density of 1.60 Mg/m3 (1.60 g/cm³). Note 1The adjusted modulus of rupture (MR A ) at any intermediate fiber concentration may be interpolated from results suitably determined over a limited spanning range of fiber concentrations. For example, the MR A at 10 % fiber concentration may be graphically determined from data at 3 and 17 %.

1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.4 Breathing of asbestos dust is hazardous. Asbestos and asbestos products present demonstrated health risks for users and for those with whom they come into contact. In addition to other precautions, when working with asbestos-cement products, minimize the dust that results. For information on the safe use of chrysotile asbestos, refer to "Safe Use of Chrysotile: A Manual on Preventive and Control Measures."

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

More ASTM standard pdf

ASTM F475-77(1998)

ASTM F475-77(1998)

Standard Specification for Test Screw Used in Screw-Retention Test of Binding Mounting Area on Alpine Skis (Withdrawn 2004)

$25.00 $50.00

ASTM C500-98(2002)

ASTM C500-98(2002)

Standard Test Methods for Asbestos-Cement Pipe

$30.00 $60.00

ASTM D2992-96e1

ASTM D2992-96e1

Standard Practice for Obtaining Hydrostatic or Pressure Design Basis for "Fiberglass" (Glass-Fiber-Reinforced Thermosetting-Resin) Pipe and Fittings

$32.00 $65.00

ASTM C1172-96e1

ASTM C1172-96e1

Standard Specification for Laminated Architectural Flat Glass

$29.00 $58.00