Standard Test Methods for Nitrite-Nitrate in Water

ASTM International, 05/15/2009

Publisher: ASTM

File Format: PDF

$33.00$67.00


Published:15/05/2009

Pages:11

File Size:1 file , 180 KB

Note:This product is unavailable in Russia, Ukraine, Belarus

1.1 These test methods cover the determination of nitrite nitrogen, nitrate nitrogen, and combined nitrite-nitrate nitrogen in water and wastewater in the range from 0.05 to 1.0 mg/L nitrogen. Two test methods are given as follows:

Sections
Test Method A-Automated Cadmium Reduction 9 to 18
Test Method B-Manual Cadmium Reduction 19 to 28

1.2 These test methods are applicable to surface, saline, waste, and ground waters. It is the user's responsibility to ensure the validity of these test methods for waters of untested matrices.

1.3 The values stated in either SI or inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Note 1 and Note 2.

9.1 The applicable range of this test method is from 0.05 to 1 mg/L of nitrite or nitrate nitrogen. The range may be extended upward by dilution of an appropriate aliquot. Many workers have found that this test method is reliable for nitrite and combined nitrite-nitrate levels to 0.01 mg N/L. However, the precision and bias data presented in this test method are insufficient to justify application of this test method in the 0.01 to 0.05 mg/L-N range.

9.2 This test method is applicable to surface, saline, waste, and ground waters. It is the user's responsibility to ensure the validity of this test method for waters of untested matrices.

19.1 The applicable range of this test method is from 0.05 to 1 mg/L of nitrite or nitrate nitrogen. The range may be extended upward by dilution of an appropriate aliquot. Many workers have found that this test method is reliable for nitrite and combined nitrite-nitrate levels to 0.01 mg N/L. However, the precision and accuracy data presented in this test method are insufficient to justify application of this test method in the 0.01 to 0.05 mg/L-N range.

19.2 This test method is applicable to surface, saline, waste, and ground waters. It is the user's responsibility to ensure the validity of this test method for waters of untested matrices.

More ASTM standard pdf

ASTM E989-18

ASTM E989-18

Standard Classification for Determination of Single-Number Metrics for Impact Noise

$27.00 $54.00

ASTM E956-83(2015)

ASTM E956-83(2015)

Standard Classification for Municipal-Mixed Nonferrous Metals (MNM)

$34.00 $68.00

ASTM D3326-07(2011)

ASTM D3326-07(2011)

Standard Practice for Preparation of Samples for Identification of Waterborne Oils

$30.00 $60.00

ASTM D3691/D3691M-09

ASTM D3691/D3691M-09

Standard Performance Specification for Woven, Lace, and Knit Household Curtain and Drapery Fabrics (Withdrawn 2018)

$26.00 $52.00