Your shopping cart is empty!
ASTM International, 10/10/1998
Publisher: ASTM
File Format: PDF
$25.00$50.00
Published:10/10/1998
Pages:3
File Size:1 file , 35 KB
Note:This product is unavailable in Russia, Ukraine, Belarus
1.1 Test Methods D301 for measuring nitrogen content in nitrocellulose by nitrometer are the accepted standard. However, the glassware is specialized and the precision is dependent on the development of a high level of skill by the operator. The ferrous-sulfate titration of nitrate is a classical procedure. By controlling critical variables and automating the actual titration, precision equivalent to the nitrometer can be achieved with nitrocellulose. This test method describes such a procedure.
1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 8.
Standard Test Method for Volatile Matter in the Analysis Sample of Coal and Coke
$27.00 $54.00
Standard Test Method for Plastics: Dynamic Mechanical Properties: In Torsion
$25.00 $50.00
Standard Specification for Ultrasonic Examination of Forged Crankshafts
Standard Test Method for Adherence of Porcelain Enamel Coatings to Sheet Metal
$29.00 $58.00