1.1 This guide covers procedures that are specifically related to permanent decommissioning (closure) of the following as applied to environmental activities. It is intended for use where solid or hazardous materials or wastes are found, or where conditions occur requiring the need for decommissioning. The following devices are considered in this guide:
1.1.1 A borehole used for geoenvironmental purposes (see Note 1),
1.1.2 Monitoring wells,
1.1.3 Observation wells,
1.1.4 Injection wells (see Note 2),
1.1.5 Piezometers,
1.1.6 Wells used for the extraction of contaminated groundwater, the removal of floating or submerged materials other than water such as gasoline or tetrachloroethylene, or other devices used for the extraction of soil gas,
1.1.7 A borehole used to construct a monitoring well, and
1.1.8 Any other well or boring that houses a vadose zone monitoring device.
1.2 Temporary decommissioning of the above is not covered in this guide.
Note 1: This guide may be used to decommission boreholes where no contamination is observed at a site (see Practice D420 for details); however, the primary use of the guide is to decommission boreholes and wells where solid or hazardous waste have been identified. Methods identified in this guide can also be used in other situations such as the decommissioning of water supply wells and boreholes where water contaminated with nonhazardous pollutants (such as nitrates or sulfates) are present. This guide should be consulted in the event that routine geotechnical studies indicate the presence of contamination at a site. Consult and follow national, state, or local regulations as they may control required decommissioning procedures.
Note 2: The term “well” is used in this guide to denote monitoring wells, piezometers, or other devices constructed in a manner similar to a well. Some of the devices listed such as injection and extraction wells can be decommissioned using this guide for information but are not specifically covered in detail in the text.
Note 3: Details on the decommissioning of multiple-screened wells are not provided in this guide due to the many methods used to construct these types of wells and the numerous types of commercially available multiple-screened well systems. However, in some instances, the methods presented in this guide may be used with few changes. An example of how this guide may be used is the complete removal of the multiple-screened wells by overdrilling.
1.3 Most monitoring wells and piezometers are intended primarily for water quality sampling, water level observation, or soil gas sampling, or combination thereof, to determine quality. Many wells are relatively small in diameter typically 2.5 to 20 cm [1 to 8 inches] and are used to monitor for hazardous chemicals in groundwater. Decommissioning of monitoring wells is necessary to:
1.3.1 Eliminate the possibility that the well is used for purposes other than intended,
1.3.2 Prevent migration of contaminants into an aquifer or between aquifers,
1.3.3 Prevent migration of contaminants in the vadose zone,
1.3.4 Reduce the potential for vertical or horizontal migration of fluids in the well or adjacent to the well, and
1.3.5 Remove the well from active use when the well is no longer capable of rehabilitation or has failed structurally; is no longer needed for monitoring; is no longer capable of providing representative samples or is providing unreliable samples; is required to be decommissioned; or to meet regulatory requirements.
Note 4: The determination of whether a well is providing a representative water quality sample is not defined in this guide. Examples of when a representative water quality sample may not be collected include the biological or chemical clogging of well screens, a drop in the water level to below the base of the well screen, or complete silting of the screen. These conditions may indicate that a well is not functioning correctly.
1.4 This guide is intended to provide information for effective permanent closure of wells so that the physical structure of the well does not provide a means of hydraulic communication between aquifers, with above surfaces or react chemically in a detrimental way with the environment.
1.5 The intent of this guide is to provide procedures that when followed result in a reasonable level of confidence in the integrity of the decommissioning activity. However, it may not be practical to verify the integrity of the decommissioning procedure. Currently, methods are not available to substantially determine the integrity of the decommissioning activity.
1.6 This guide may also be used for closure or decommissioning of other systems that could allow vertical or horizontal migration of contaminants or other cross-contamination of aquifers, such as dug wells, geothermal loops, or when ordered by regulatory agencies.
1.7 Units-The values stated in either SI units or inch-pound units (given in brackets) are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.
1.8 All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice ASTM C1178/C1178M-99 Standard Specification for Glass Mat Water-Resistant Gypsum Backing Panel $25.00 $50.00 Add to Cart ASTM C265-99 Standard Test Method for Water-Extractable Sulfate in Hydrated Hydraulic Cement Mortar $25.00 $50.00 Add to Cart ASTM F2092-01 Standard Specification for Convection Oven Gas or Electric $29.00 $58.00 Add to Cart ASTM D6661-01 Standard Practice for Field Collection of Organic Compounds from Surfaces Using Wipe Sampling $25.00 $50.00 Add to Cart
Standard Specification for Glass Mat Water-Resistant Gypsum Backing Panel
$25.00 $50.00
Standard Test Method for Water-Extractable Sulfate in Hydrated Hydraulic Cement Mortar
Standard Specification for Convection Oven Gas or Electric
$29.00 $58.00
Standard Practice for Field Collection of Organic Compounds from Surfaces Using Wipe Sampling