Your shopping cart is empty!
ASTM International, 05/01/2012
Publisher: ASTM
File Format: PDF
$30.00$60.00
Published:01/05/2012
Pages:7
File Size:1 file , 120 KB
Note:This product is unavailable in Russia, Ukraine, Belarus
1.1 This test method covers the determination of the degree and rate of anaerobic biodegradation of plastic materials in high-solids anaerobic conditions. The test materials are exposed to a methanogenic inoculum derived from anaerobic digesters operating only on pretreated household waste. The anaerobic decomposition takes place under high-solids (more than 30 % total solids) and static non-mixed conditions.
1.2 This test method is designed to yield a percentage of conversion of carbon in the sample to carbon in the gaseous form under conditions found in high-solids anaerobic digesters, treating municipal solid waste (1, 2, 3, 4). This test method may also resemble some conditions in biologically active landfills where the gas generated is recovered and biogas production is actively promoted by inoculation (for example, codeposition of anaerobic sewage sludge, anaerobic leachate recirculation), moisture control (for example, leachate recirculation), and temperature control (for example, short-term injection of oxygen, heating of recirculated leachate) (5, 6, 7).
1.3 This test method is designed to be applicable to all plastic materials that are not inhibitory to the microorganisms present in anaerobic digesters operating on household waste.
1.4 Claims of performance shall be limited to the numerical result obtained in the test and not be used for unqualified "biodegradable" claims. Reports shall clearly state the percentage of net gaseous carbon generation for both the test and reference samples at the completion of the test. Furthermore, results shall not be extrapolated past the actual duration of the test.
1.5 The values given in SI units are to be regarded as the standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazards are given in Section 8.
Note 1 - This test method is equivalent to ISO 15985.
Standard Test Method for Trace Metallic Impurities in Electronic Grade Aluminum-Copper, Aluminum-Silicon, and Aluminum-Copper-Silicon Alloys by High-Mass-Resolution Glow Discharge Mass Spectrometer
$25.00 $50.00
Standard Practice for Measuring Payback for Investments in Buildings and Building Systems
$29.00 $58.00
Standard Practice for Calibrating the Magnification of a Scanning Electron Microscope
$30.00 $60.00
Standard Specification for Standard Atmospheres for Conditioning and Testing Flexible Barrier Materials
$26.00 $52.00