1.1 These test methods cover laboratory compaction methods used to determine the relationship between molding water content and dry unit weight of soils (compaction curve) compacted in a 4 or 6-in. (101.6 or 152.4-mm) diameter mold with a 5.50-lbf (24.5-N) rammer dropped from a height of 12.0 in. (305 mm) producing a compactive effort of 12 400 ft-lbf/ft³ (600 kN-m/m³).
1.1.1 Soils and soil-aggregate mixtures are to be regarded as natural occurring fine- or coarse-grained soils, or composites or mixtures of natural soils, or mixtures of natural and processed soils or aggregates such as gravel or crushed rock. Hereafter referred to as either soil or material.
1.2 These test methods apply only to soils (materials) that have 30 % or less by mass of particles retained on the ³/4-in. (19.0-mm) sieve and have not been previously compacted in the laboratory; that is, do not reuse compacted soil.
1.2.1 For relationships between unit weights and molding water contents of soils with 30 % or less by mass of material retained on the ³/4-in. (19.0-mm) sieve to unit weights and molding water contents of the fraction passing ³/4-in. (19.0-mm) sieve, see Practice D4718.
1.3 Three alternative methods are provided. The method used shall be as indicated in the specification for the material being tested. If no method is specified, the choice should be based on the material gradation.
1.3.1 Method A:
1.3.1.1 Mold-4-in. (101.6-mm) diameter.
1.3.1.2 Material-Passing No. 4 (4.75-mm) sieve.
1.3.1.3 Layers-Three.
1.3.1.4 Blows per Layer-25.
1.3.1.5 Usage-May be used if 25 % or less (see 1.4) by mass of the material is retained on the No. 4 (4.75-mm) sieve.
1.3.1.6 Other Usage-If this gradation requirement cannot be met, then Method C may be used.
1.3.2 Method B:
1.3.2.1 Mold-4-in. (101.6-mm) diameter.
1.3.2.2 Material-Passing ³/8-in. (9.5-mm) sieve.
1.3.2.3 Layers-Three.
1.3.2.4 Blows per Layer-25.
1.3.2.5 Usage-May be used if 25 % or less (see 1.4) by mass of the material is retained on the ³/8-in. (9.5-mm) sieve.
1.3.2.6 Other Usage-If this gradation requirement cannot be met, then Method C may be used.
1.3.3 Method C:
1.3.3.1 Mold-6-in. (152.4-mm) diameter.
1.3.3.2 Material-Passing ³/4-in. (19.0-mm) sieve.
1.3.3.3 Layers-Three.
1.3.3.4 Blows per Layer-56.
1.3.3.5 Usage-May be used if 30 % or less (see 1.4) by mass of the material is retained on the ³/4-in. (19.0-mm) sieve.
1.3.4 The 6-in. (152.4-mm) diameter mold shall not be used with Method A or B.
1.4 If the test specimen contains more than 5 % by mass of oversize fraction (coarse fraction) and the material will not be included in the test, corrections must be made to the unit mass and molding water content of the specimen or to the appropriate field-in-place density test specimen using Practice D4718.
1.5 This test method will generally produce a well-defined maximum dry unit weight for non-free draining soils. If this test method is used for free-draining soils the maximum unit weight may not be well defined, and can be less than obtained using Test Methods D4253.
1.6 All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D6026, unless superseded by this standard.
1.6.1 For purposes of comparing measured or calculated value(s) with specified limits, the measured or calculated value(s) shall be rounded to the nearest decimal or significant digits in the specified limits.
1.6.2 The procedures used to specify how data are collected/recorded or calculated, in this standard are regarded as the industry standard. In addition, they are representative of the significant digits that generally should be retained. The procedures used do not consider material variation, purpose for obtaining the data, special purpose studies, or any considerations for the user's objectives; and it is common practice to increase or reduce significant digits of reported data to be commensurate with these considerations. It is beyond the scope of this standard to consider significant digits used in analytical methods for engineering design.
1.7 The values in inch-pound units are to be regarded as the standard. The values stated in SI units are provided for information only, except for units of mass. The units for mass are given in SI units only, g or kg.
1.7.1 It is common practice in the engineering profession to concurrently use pounds to represent both a unit of mass (lbm) and a force (lbf). This implicitly combines two separate systems of units; that is, the absolute system and the gravitational system. It is scientifically undesirable to combine the use of two separate sets of inc
Standard Practice for Measuring Viscosity of Glass Above the Softening Point
$30.00 $60.00
Standard Test Method for Determining Seam Strength in Inflatable Restraint Cushions
Standard Specification for Fabrication of Cellular Glass Pipe and Tubing Insulation
$25.00 $50.00
Standard Test Method for Color of Naval Stores and Related Products (Instrumental Determination of Gardner Color)
$26.00 $52.00