1.1 This procedure covers the determination of thiodiglycol (TDG) in surface water by direct injection using liquid chromatography (LC) and detected with tandem mass spectrometry (MS/MS). TDG is qualitatively and quantitatively determined by this test method. This test method adheres to single reaction monitoring (SRM) mass spectrometry.
1.2 This test method has been developed by U.S. EPA Region 5 Chicago Regional Laboratory (CRL).
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 The detection verification level (DVL) and reporting range for TDG are listed in Table 1.
Analyte
DVL (μg/L)
Reporting Range (μg/L)
Thiodiglycol
20
100-10 000
1.4.1 The DVL is required to be at a concentration at least 3 times below the reporting limit (RL) and have a signal/noise ratio greater than 3:1. Fig. 1 displays the signal/noise ratio at the DVL.
FIG. 1 Example SRM Chromatograms Signal/Noise at Detection Verification Level
1.4.2 The RL is the concentration of the Level 1 calibration standard as shown in Table 2. The reporting limit for this test method is 100 μg/L.
Analyte/Surrogate
LV 1
LV 2
LV 3
LV 4
LV 5
LV 6
LV 7
Standard Specification for Corrugated High Density Polyethylene (HDPE) Water Quality Units
$29.00 $58.00
Standard Test Method for Density (Relative Density) of Solid Pitch (Pycnometer Method)
$26.00 $52.00
Standard Specification for "Twist Off" Type Tension Control Structural Bolt/Nut/Washer Assemblies, Steel, Heat Treated, 120/105 ksi Minimum Tensile Strength
Standard Test Methods for Determining Acceptability of Ribbon Welds in Fabric Cartridges