1.1 This standard practice describes standard procedures for using a conductive geotextile with electrical methods to locate leaks in exposed geomembranes and geomembranes covered with water or earth materials containing moisture.
1.2 This standard practice provides guidance for the use of appropriate conductive geotextile used in leak location survey on geomembrane. This guide includes all types of conductive geotextile with sufficient conductivity for the particular electrical leak location method. A conductive geotextile is applicable to all types of geoelectric surveys when there is otherwise not a conductive layer under the geomembrane.
1.3 The leak stream itself being adequately conductive. A conductive geotextile is applicable to all types of geoelectric surveys when there is otherwise not a conductive layer under the geomembrane.
1.4 This standard practice is intended to ensure that leak location surveys can always be performed with a reasonable level of certainty. This standard practice provides guidance for the use of appropriate conductive geotextile used in leak location survey on geomembranes.
1.5 Leak location surveys can be used on non-conductive geomembranes installed in basins, ponds, tanks, ore and waste pads, landfill cells, landfill caps, other containment facilities and building applications such as in parking garages, decks and green roofs. The procedures are applicable for geomembranes made of non conductive materials such as polyethylene, polypropylene, polyvinyl chloride, chlorosulfonated polyethylene, bituminous material, and other electrically-insulating materials. Leak location survey involving conductive or partially conductive geomembranes are not within the scope of this document.
1.6 Warning-The electrical methods used for geomembrane leak location could use high voltages, resulting in the potential for electrical shock or electrocution. This hazard might be increased because operations might be conducted in or near water. In particular, a high voltage could exist between the water or earth material and earth ground, or any grounded conductor. These procedures are potentially VERY DANGEROUS, and can result in personal injury or death. Because of the high voltage that could be involved, and the shock or electrocution hazard, do not come in electrical contact with any leak unless the excitation power supply is turned off. The electrical methods used for geomembrane leak location should be attempted only by qualified and experienced personnel. Appropriate safety measures must be taken to protect the leak location operators as well as other people at the site.
1.7 This standard guide does not purport to address all of the safety and liability concerns, if any, associated with its use. It is the responsibility of the user of this standard guide to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Standard Guide for Conducting a Sensitivity Analysis for a Groundwater Flow Model Application
$24.00 $48.00
Standard Test Method for Insoluble Contamination of Hydraulic Fluids by Gravimetric Analysis
$21.00 $42.00
Standard Practice for Minimum Structural Design Loading for Monolithic or Sectional Precast Concrete Utility, Water, and Wastewater Structures Using AASHTO LRFD Design
$31.00 $62.00
Standard Specification for Seamless Carbon Steel Pipe for Atmospheric and Lower Temperatures