• ASTM E1-07

ASTM E1-07

Standard Specification for ASTM Liquid-in-Glass Thermometers

ASTM International, 11/01/2007

Publisher: ASTM

File Format: PDF

$50.00$101.00


Published:01/11/2007

Pages:64

File Size:1 file , 330 KB

Note:This product is unavailable in Russia, Ukraine, Belarus

p>1.1 This specification covers liquid-in-glass thermometers graduated in degrees Celsius or degrees Fahrenheit that are frequently identified and used in methods under the jurisdiction of the various technical committees within ASTM. The various thermometers specified are listed in Table 1 . The inclusion of an IP number in Table 1 indicates, where appearing, that the thermometer specification has been jointly agreed upon by the British Institute of Petroleum (IP) and ASTM.

1.2 This specification also covers adjustable-range enclosed-scale thermometers, graduated in degrees Celsius, which are used in ASTM methods.

1.3 The enclosed-scale thermometers are commonly called Beckmann thermometers. They are suitable for measuring small temperature differences not exceeding 6 C within a larger range of temperature. The thermometers are unsuitable for measuring Celsius- or kelvin-scale temperatures unless they have been compared with standard instruments immediately before use.

1.4 An alphabetic list of the ASTM Thermometers included in this standard is given in Table 2 .

1.5 A list of ASTM Thermometers is given in to facilitate selection according to temperature range, immersion, and scale-error requirements. Note 1 - For a listing of thermometers recommended for general laboratory use, the Scientific Apparatus Makers Association Specifications for General Purpose Glass Laboratory Thermometers may be consulted.

Note 2 - It has been found by experience that these ASTM Thermometers, although developed in general for specific tests, may also be found suitable for other applications, thus precluding the need for new thermometer specifications differing in only minor features. However, it is suggested that technical committees contact Subcommittee E20.05 before choosing a currently specified thermometer for a new method to be sure the thermometer will be suitable for the intended application.

1.6 For non-mercury alternatives to E1 thermometers see Specification E 2251.

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

1.8 WARNING- Mercury has been designated by EPA and many state agencies as a hazardous material that can cause central nervous system, kidney and liver damage. Mercury, or its vapor, may be hazardous to health and corrosive to materials. Caution should be taken when handling mercury and mercury containing products. See the applicable product Material Safety Data Sheet (MSDS) for details and EPAs website- http://www.epa.gov/mercury/faq.htm - for additional information. Users should be aware that selling mercury and/or mercury containing products into your state may be prohibited by state law.

More ASTM standard pdf

ASTM E605-93(2006)

ASTM E605-93(2006)

Standard Test Methods for Thickness and Density of Sprayed Fire-Resistive Material (SFRM) Applied to Structural Members

$30.00 $60.00

ASTM B19-05

ASTM B19-05

Standard Specification for Cartridge Brass Sheet, Strip, Plate, Bar, and Disks

$30.00 $60.00

ASTM E989-06

ASTM E989-06

Standard Classification for Determination of Impact Insulation Class (IIC)

$25.00 $50.00

ASTM F2472-05

ASTM F2472-05

Standard Test Method for Performance of Staff-Serve Hot Deli Cases

$29.00 $58.00