• ASTM E1125-16

ASTM E1125-16

Standard Test Method for Calibration of Primary Non-Concentrator Terrestrial Photovoltaic Reference Cells Using a Tabular Spectrum

ASTM International, 07/01/2016

Publisher: ASTM

File Format: PDF

$30.00$60.00


Published:01/07/2016

Pages:10

File Size:1 file , 140 KB

Note:This product is unavailable in Russia, Ukraine, Belarus

1.1 This test method is intended for calibration and characterization of primary terrestrial photovoltaic reference cells to a desired reference spectral irradiance distribution, such as Tables G173. The recommended physical requirements for these reference cells are described in Specification E1040. Reference cells are principally used in the determination of the electrical performance of photovoltaic devices.

1.2 Primary photovoltaic reference cells are calibrated in natural sunlight using the relative quantum efficiency of the cell, the relative spectral distribution of the sunlight, and a tabulated reference spectral irradiance distribution. Selection of the reference spectral irradiance distribution is left to the user.

1.3 This test method requires the use of a pyrheliometer that is calibrated according to Test Method E816, which requires the use of a pyrheliometer that is traceable to the World Radiometric Reference (WRR). Therefore, reference cells calibrated according to this test method are traceable to the WRR.

1.4 This test method is used to calibrate primary reference cells; Test Method E1362 may be used to calibrate secondary and non-primary reference cells (these terms are defined in Terminology E772).

1.5 This test method applies only to the calibration of a photovoltaic cell that shows a linear dependence of its short-circuit current on irradiance over its intended range of use, as defined in Test Method E1143.

1.6 This test method applies only to the calibration of a reference cell fabricated with a single photovoltaic junction.

1.7 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

More ASTM standard pdf

ASTM D1218-12(2016)

ASTM D1218-12(2016)

Standard Test Method for Refractive Index and Refractive Dispersion of Hydrocarbon Liquids

$34.00 $68.00

ASTM E1869-04(2014)

ASTM E1869-04(2014)

Standard Guide for Confidentiality, Privacy, Access, and Data Security Principles for Health Information Including Electronic Health Records (Withdrawn 2017)

$29.00 $58.00

ASTM E872-82(2006)

ASTM E872-82(2006)

Standard Test Method for Volatile Matter in the Analysis of Particulate Wood Fuels

$26.00 $52.00

ASTM D3670-91(2014)

ASTM D3670-91(2014)

Standard Guide for Determination of Precision and Bias of Methods of Committee D22

$34.00 $68.00