1.1 This guide covers procedures for obtaining laboratory data concerning the adverse effects of an aqueous effluent on certain species of freshwater and saltwater fishes, macroinvertebrates, and amphibians, usually during 2 day to 4 day exposures, depending on the species, using the static, renewal, and flow-through techniques. These procedures will probably be useful for conducting acute toxicity tests on aqueous effluents with many other aquatic species, although modifications might be necessary.
1.2 Other modifications of these procedures might be justified by special needs or circumstances. Although using appropriate procedures is more important than following prescribed procedures, results of tests conducted using unusual procedures are not likely to be comparable to results of many other tests. Comparison of results obtained using modified and unmodified versions of these procedures might provide useful information concerning new concepts and procedures for conducting acute toxicity tests on aqueous effluents.
1.3 This guide is based in large part on Guide E729 where addition details are provided for test elements that may be applicable to the ambient and effluent toxicity testing described in this method. The major differences between the two guides are (1) the maximum test concentration is 100 % effluent or ambient sample, (2) testing is not chemical-specific, and (3) the holding time of effluent and ambient samples is often considerably less than that for chemicals and other test materials. Because the sample is often a complex mixture of chemicals, analytical tests cannot generally be used to confirm exposure concentrations.
1.4 Selection of the technique to be used in a specific situation will depend upon the needs of the investigator and upon available resources. Static tests provide the most easily obtained measure of acute toxicity but should not last longer than 48 h. Renewal and flow-through tests may last longer than 48 h because the pH and concentrations of dissolved oxygen and effluent are maintained at desired levels and degradation and metabolic products are removed. Static tests might not be applicable to effluents that have a high oxygen demand or contain materials that (1) are highly volatile, (2) are rapidly biologically or chemically transformed in aqueous solutions, or (3) are removed from test solutions in substantial quantities by the test chambers or organisms during the test. Flow-through tests are generally preferable to renewal tests, although in some situations a renewal test might be more cost-effective than a flow-through test.
1.5 In the development of these procedures, an attempt was made to balance scientific and practical considerations and to ensure that the results will be sufficiently accurate and precise for the applications for which they are commonly used. A major consideration was that the common uses of the results of acute tests on effluents do not require or justify stricter requirements than those set forth in this guide. Although the tests may be improved by using more organisms, longer acclimation times, and so forth, the requirements presented in this guide should usually be sufficient.
1.6 Results of acute toxicity tests should usually be reported in terms of a median lethal concentration (LC50) or median effective concentration (EC50). In some situations, it might be necessary only to determine whether a specific concentration is acutely toxic to the test species or whether the LC50 or EC50 is above or below a specific concentration.
1.7 This guide is arranged as follows:
  Section     Referenced Documents   2 Terminology   3 Summary of Guide   4 Significance and Use   5 Hazards   7 Apparatus   6  Facilities   6.1  Special Requirements   6.2  Construction Materials   6.3  Metering System   6.4  Test Chambers   6.5  Cleaning   6.6  Acceptability   6.7 Dilution Water   8  Requirements   8.1  Source   8.2  Treatment   8.3  Characterization   8.4 Effluent   9  Sampling Point   9.1  Collection   9.2  Preservation   9.3  Treatment   9.4  Test Concentration(s)   9.5 Test Organisms   10  Species   10.1  Age   10.2  Source   10.3  Care and Handling   10.4  Feeding   10.5  Disease Treatment   10.6  Holding   10.7  Acclimation   10.8  Quality   10.9 Procedure   11  Experimental Design   11.1  Dissolved Oxygen   11.2  Temperature   11.3  Loading   11.4  Beginning the Test   11.5  Feeding   11.6  Duration of Test   11.7  Biological Data   11.8  Other Measurements   11.9 Analytical Methodology   12 Acceptability of Test   13 Calculation or Results   14 Report   15
1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limit

More ASTM standard pdf

ASTM F1200-88(2004)

ASTM F1200-88(2004)

Standard Specification for Fabricated (Welded) Pipe Line Strainers (Above 150 psig and 150 degrees F)

$25.00 $50.00

ASTM F887-04

ASTM F887-04

Standard Specifications for Personal Climbing Equipment

$32.00 $65.00

ASTM D3235-04

ASTM D3235-04

Standard Test Method for Solvent Extractables in Petroleum Waxes

$30.00 $60.00

ASTM F1216-03

ASTM F1216-03

Standard Practice for Rehabilitation of Existing Pipelines and Conduits by the Inversion and Curing of a Resin-Impregnated Tube

$29.00 $58.00