Standard Practice for Sampling for Particulate Contamination by Tape Lift

ASTM International, 10/01/2016

Publisher: ASTM

File Format: PDF

$32.00$64.00


Published:01/10/2016

Pages:5

File Size:1 file , 86 KB

Note:This product is unavailable in Russia, Ukraine, Belarus

1.1 This practice covers procedures for sampling surfaces to determine the presence of particulate contamination, 5 μm and larger. The practice consists of the application of a pressure-sensitive tape to the surface followed by the removal of particulate contamination with the removal of the tape. The tape with the adhering particles is then mounted on counting slides. Counting and measuring of particles is done by standard techniques.

1.2 This practice describes the materials and equipment required to perform sampling of surfaces for particle counting and sizing.

1.3 The criteria for acceptance or rejection of a part for conformance to surface cleanliness level requirements shall be determined by the user and are not included in this practice.

1.4 This practice is for use on surfaces that are not damaged by the application of adhesive tape. The use of this practice on any surface of any material not previously tested, or for which the susceptibility to damage is unknown, is not recommended. In general, metals, metal plating, and oxide coatings will not be damaged. Application to painted, vapor deposited, and optical coatings should be evaluated before implementing this test.

1.5 This practice provides three methods to evaluate tape lift tests, as follows:

 

Sections

 

 

Practice A-This method uses light transmitted through the tape
 and tape adhesive to detect particles that adhere to it.

4 to 6

 

Practice B-This method uses light transmitted through the tape
 adhesive after bonding to a base microscope slide, dissolving
 the tape backing, and a cover slide. The particles are embedded
 in the adhesive, and air bubbles are eliminated with acrylic
 mounting media.

7 to 9

 

Practice C-This method uses light reflected off the tape adhesive
 to detect particles that adhere to it.

10 to 12

1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.6.1 Exception-The inch-pound units given in parentheses are for information only.

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

More ASTM standard pdf

ASTM D5237-92e1

ASTM D5237-92e1

Standard Guide for Evaluating Fabric Softeners (Withdrawn 2001)

$29.00 $58.00

ASTM D511-93(1998)

ASTM D511-93(1998)

Standard Test Methods for Calcium and Magnesium In Water

$31.00 $62.00

ASTM E671-98

ASTM E671-98

Standard Specification for Maximum Permissible Thermal Residual Stress in Annealed Glass Laboratory Apparatus

$25.00 $50.00

ASTM F1882-98

ASTM F1882-98

Standard Specification for Residential Basketball Systems

$29.00 $58.00