Standard Practice for Sampling for Particulate Contamination by Tape Lift

ASTM International, 09/01/2021

Publisher: ASTM

File Format: PDF

$27.00$54.00


Published:01/09/2021

Pages:5

File Size:1 file , 86 KB

Note:This product is unavailable in Russia, Ukraine, Belarus

1.1''This practice covers procedures for sampling surfaces to determine the presence of particulate contamination, 5 ''m and larger. The practice consists of the application of a pressure-sensitive tape to the surface followed by the removal of particulate contamination with the removal of the tape. The tape with the adhering particles is then mounted on counting slides. Counting and measuring of particles is done by standard techniques.

1.2''This practice describes the materials and equipment required to perform sampling of surfaces for particle counting and sizing.

1.3''The criteria for acceptance or rejection of a part for conformance to surface cleanliness level requirements shall be determined by the user and are not included in this practice.

1.4''This practice is for use on surfaces that are not damaged by the application of adhesive tape. The use of this practice on any surface of any material not previously tested, or for which the susceptibility to damage is unknown, is not recommended. In general, metals, metal plating, and oxide coatings will not be damaged. Application to painted, vapor deposited, and optical coatings should be evaluated before implementing this test.

1.5''This practice provides three methods to evaluate tape lift tests, as follows:

Practice

Sections

''

''

A'''This method uses light transmitted through the tape and tape adhesive to detect particles that adhere to it.

4 to 6

''

B'''This method uses light transmitted through the tape adhesive after bonding to a base microscope slide, dissolving the tape backing, and a cover slide. The particles are embedded in the adhesive, and air bubbles are eliminated with acrylic mounting media.

7 to 9

''

C'''This method uses light reflected off the tape adhesive to detect particles that adhere to it.

10 to 12

1.6''Units'''The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard.

1.7''This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.8''This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

More ASTM standard pdf

ASTM D4177-16

ASTM D4177-16

Standard Practice for Automatic Sampling of Petroleum and Petroleum Products

$48.00 $97.00

ASTM D4476/D4476M-14

ASTM D4476/D4476M-14

Standard Test Method for Flexural Properties of Fiber Reinforced Pultruded Plastic Rods (Withdrawn 2022)

$34.00 $68.00

ASTM D7042-14

ASTM D7042-14

Standard Test Method for Dynamic Viscosity and Density of Liquids by Stabinger Viscometer (and the Calculation of Kinematic Viscosity)

$30.00 $60.00

ASTM E1982-98(2007)

ASTM E1982-98(2007)

Standard Practice for Open-Path Fourier Transform Infrared (OP/FT-IR) Monitoring of Gases and Vapors in Air

$32.00 $65.00