• ASTM E1249-10

ASTM E1249-10

Standard Practice for Minimizing Dosimetry Errors in Radiation Hardness Testing of Silicon Electronic Devices Using Co-60 Sources

ASTM International, 12/01/2010

Publisher: ASTM

File Format: PDF

$32.00$65.00


Published:01/12/2010

Pages:16

File Size:1 file , 280 KB

Note:This product is unavailable in Russia, Ukraine, Belarus

1.1 This practice covers recommended procedures for the use of dosimeters, such as thermoluminescent dosimeters (TLD's), to determine the absorbed dose in a region of interest within an electronic device irradiated using a Co-60 source. Co-60 sources are commonly used for the absorbed dose testing of silicon electronic devices.

Note 1 - This absorbed-dose testing is sometimes called "total dose testing" to distinguish it from "dose rate testing."

Note 2 - The effects of ionizing radiation on some types of electronic devices may depend on both the absorbed dose and the absorbed dose rate; that is, the effects may be different if the device is irradiated to the same absorbed-dose level at different absorbed-dose rates. Absorbed-dose rate effects are not covered in this practice but should be considered in radiation hardness testing.

1.2 The principal potential error for the measurement of absorbed dose in electronic devices arises from non-equilibrium energy deposition effects in the vicinity of material interfaces.

1.3 Information is given about absorbed-dose enhancement effects in the vicinity of material interfaces. The sensitivity of such effects to low energy components in the Co-60 photon energy spectrum is emphasized.

1.4 A brief description is given of typical Co-60 sources with special emphasis on the presence of low energy components in the photon energy spectrum output from such sources.

1.5 Procedures are given for minimizing the low energy components of the photon energy spectrum from Co-60 sources, using filtration. The use of a filter box to achieve such filtration is recommended.

1.6 Information is given on absorbed-dose enhancement effects that are dependent on the device orientation with respect to the Co-60 source.

1.7 The use of spectrum filtration and appropriate device orientation provides a radiation environment whereby the absorbed dose in the sensitive region of an electronic device can be calculated within defined error limits without detailed knowledge of either the device structure or of the photon energy spectrum of the source, and hence, without knowing the details of the absorbed-dose enhancement effects.

1.8 The recommendations of this practice are primarily applicable to piece-part testing of electronic devices. Electronic circuit board and electronic system testing may introduce problems that are not adequately treated by the methods recommended here.

1.9 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

More ASTM standard pdf

ASTM D3891-08(2014)

ASTM D3891-08(2014)

Standard Practice for Preparation of Glass Panels for Testing Paint, Varnish, Lacquer, and Related Products

$26.00 $52.00

ASTM E644-09

ASTM E644-09

Standard Test Methods for Testing Industrial Resistance Thermometers

$43.00 $86.00

ASTM Volume 01.08:2014

ASTM Volume 01.08:2014

ASTM Book of Standards Volume 01.08: Iron and Steel Products - Fasteners, Rolling Element Bearings

$132.00 $264.39

ASTM E2027-09

ASTM E2027-09

Standard Practice for Conducting Proficiency Tests in the Chemical Analysis of Metals, Ores, and Related Materials

$29.00 $58.00