1.1 This test method describes the analysis of aluminum and its alloys by atomic emission spectrometry. The aluminum specimen to be analyzed may be in the form of a chill cast disk, casting, foil, sheet, plate, extrusion, or some other wrought form or shape. The elements covered in the scope of this method are listed in the table below.

Element

Tested Concentration Range
(Wt %)

Antimony

   0.001 to 0.003

Arsenic

   0.001 to 0.006

Beryllium

   0.0004 to 0.24

Bismuth

   0.03 to 0.6

Boron

   0.0006 to 0.009

Calcium

   0.0002 to -

Chromium

   0.001 to 0.23

Cobalt

   0.4 to -

Copper

   0.001 to 5.5

Gallium

   0.02 to -

Iron

   0.2 to 0.5

Lead

   0.04 to 0.6

Lithium

   0.0003 to 2.1

Magnesium

   0.03 to 5.4

Manganese

   0.001 to 1.2

Nickel

   0.005 to 2.6

Phosphorus

   0.003 to -

Silicon

   0.07 to 16

Sodium

   0.003 to 0.02

Strontium

   0.03 to -

Tin

   0.03 to -

Titanium

   0.001 to 0.12

Vanadium

   0.002 to 0.022

Zinc

   0.002 to 5.7

Zirconium

   0.001 to 0.12

Note 1: The concentration ranges given in the above scope were established through cooperative testing (ILS) of selected reference materials. The range shown for each element does not demonstrate the actual usable analytical range for that element. The usable analytical range may be extended higher or lower based on individual instrument capability, spectral characteristics of the specific element wavelength being used, and the availability of appropriate reference materials.

Note 2: Mercury (Hg) is intentionally not included in the scope. Analysis of Hg in aluminum by spark atomic emission spectrometry (Spark-AES) is not recommended. Accurate analysis of Hg using this technique is compromised by the presence of an intense iron interference. Inaccurate reporting of Hg due to these interference effects can jeopardize the current designation of aluminum production as a mercury-free process. To demonstrate compliance with legislated Hg content limits, use of an alternate method capable of analysis with a minimum reporting limit of 0.0001% or lower is recommended. Suitable techniques include but are not limited to glow discharge mass spectrometry, XRF, and cold vapor AA.

1.2 This test method is suitable primarily for the analysis of chill cast disks as defined in Practices E716. Other forms may be analyzed, provided that: (1) they are sufficiently massive to prevent undue heating, (2) they allow machining to provide a clean, flat surface, which creates a seal between the specimen and the spark stand, and (3) reference materials of a similar metallurgical condition and chemical composition are available.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific safety and health statements are given in Section 10.

More ASTM standard pdf

ASTM D1610-18

ASTM D1610-18

Standard Practice for Conditioning Leather and Leather Products for Testing

$30.00 $60.00

ASTM F2924-12

ASTM F2924-12

Standard Specification for Additive Manufacturing Titanium-6 Aluminum-4 Vanadium with Powder Bed Fusion

$29.00 $58.00

ASTM A529/A529M-00

ASTM A529/A529M-00

Standard Specification for High-Strength Carbon-Manganese Steel of Structural Quality

$26.00 $52.00

ASTM C1761/C1761M-15

ASTM C1761/C1761M-15

Standard Specification for Lightweight Aggregate for Internal Curing of Concrete

$29.00 $58.00