• ASTM E1251-17a

ASTM E1251-17a

Standard Test Method for Analysis of Aluminum and Aluminum Alloys by Spark Atomic Emission Spectrometry

ASTM International, 10/01/2017

Publisher: ASTM

File Format: PDF

$24.00$48.00


Published:01/10/2017

Pages:10

File Size:1 file , 120 KB

Note:This product is unavailable in Russia, Ukraine, Belarus

1.1 This test method describes the analysis of aluminum and its alloys by spark-atomic emission spectrometry (Spark-AES). The aluminum specimen to be analyzed may be in the form of a chill cast disk, casting, foil, sheet, plate, extrusion, or some other wrought form or shape. The elements covered in the scope of this method are listed in the table below.

Element

Tested Mass Fraction Range
(Wt %)

Antimony

   0.001 to 0.003

Arsenic

   0.001 to 0.006

Beryllium

   0.0004 to 0.24

Bismuth

   0.03 to 0.6

Boron

   0.0006 to 0.009

Calcium

   0.0002 to -

Chromium

   0.001 to 0.23

Cobalt

   0.4 to -

Copper

   0.001 to 5.5

Gallium

   0.02 to -

Iron

   0.2 to 0.5

Lead

   0.04 to 0.6

Lithium

   0.0003 to 2.1

Magnesium

   0.03 to 5.4

Manganese

   0.001 to 1.2

Nickel

   0.005 to 2.6

Phosphorus

   0.003 to -

Silicon

   0.07 to 16

Sodium

   0.003 to 0.02

Strontium

   0.03 to -

Tin

   0.03 to -

Titanium

   0.001 to 0.12

Vanadium

   0.002 to 0.022

Zinc

   0.002 to 5.7

Zirconium

   0.001 to 0.12

Note 1: The mass fraction ranges given in the above scope were established through cooperative testing (ILS) of selected reference materials. The range shown for each element does not demonstrate the actual usable analytical range for that element. The usable analytical range may be extended higher or lower based on individual instrument capability, spectral characteristics of the specific element wavelength being used, and the availability of appropriate reference materials.

Note 2: Mercury (Hg) is intentionally not included in the scope. Analysis of Hg in aluminum by Spark-AES is not recommended. Accurate analysis of Hg using this technique is compromised by the presence of an intense iron interference. Inaccurate reporting of Hg due to these interference effects can jeopardize the current designation of aluminum production as a mercury-free process. To demonstrate compliance with legislated Hg content limits, use of an alternate method capable of analysis with a minimum reporting limit of 0.0001% or lower is recommended. Suitable techniques include but are not limited to GD-MS, XRF (X-ray fluorescence), cold vapor AA, and ICP-MS.

1.2 This test method is suitable primarily for the analysis of chill cast disks as defined in Practices E716. Other forms may be analyzed, provided that: (1) they are sufficiently massive to prevent undue heating, (2) they allow machining to provide a clean, flat surface, which creates a seal between the specimen and the spark stand, and (3) reference materials of a similar metallurgical condition and chemical composition are available.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific safety and health statements are given in Section 10.

ASTM A182/A182M-22a

ASTM A182/A182M-22a

Standard Specification for Forged or Rolled Alloy and Stainless Steel Pipe Flanges, Forged Fittings, and Valves and Parts for High-Temperature Service

$38.00 $76.00

ASTM E1299-96(2023)

ASTM E1299-96(2023)

Standard Specification for Reusable Phase-Change-Type Fever Thermometer for Intermittent Determination of Human Temperature

$25.00 $50.00

ASTM D3782-22

ASTM D3782-22

Standard Performance Specification for Men's and Boys' Knitted Dress Suit Fabrics and Knitted Sportswear Jacket, Slack, and Trouser Fabrics

$25.00 $50.00

ASTM G77-17(2022)

ASTM G77-17(2022)

Standard Test Method for Ranking Resistance of Materials to Sliding Wear Using Block-on-Ring Wear Test

$31.00 $63.00