• ASTM E1662-95a(2018)

ASTM E1662-95a(2018)

Standard Classification for Serviceability of an Office Facility for Sound and Visual Environment

ASTM International, 03/01/2018

Publisher: ASTM

File Format: PDF

$28.00$56.00


Published:01/03/2018

Pages:12

File Size:1 file , 2 MB

Note:This product is unavailable in Russia, Ukraine, Belarus

1.1 This classification covers pairs of scales for classifying an aspect of the serviceability of an office facility, that is, the capability of an office facility to meet certain possible requirements for suitable sound and visual conditions.

1.2 Within that aspect of serviceability, each pair of scales, shown in Figs. 1-6, are for classifying one topic of serviceability. Each paragraph in an Occupant Requirement Scale (see Figs. 1-6) summarizes one level of serviceability on that topic, which occupants might require. The matching entry in the Facility Rating Scale (see Figs. 1-6) is a translation of the requirement into a description of certain features of a facility which, taken in combination, indicate that the facility is likely to meet that level of required serviceability.

FIG. 1 Scale A.3.1 for Privacy and Speech Intelligibility

Scale A.3.1 for Privacy and Speech IntelligibilityScale A.3.1 for Privacy and Speech Intelligibility

FIG. 1 Scale A.3.1 for Privacy and Speech Intelligibility (continued)

Scale A.3.1 for Privacy and Speech IntelligibilityScale A.3.1 for Privacy and Speech Intelligibility

FIG. 2 Scale A.3.2 for Distraction and Disturbance

Scale A.3.2 for Distraction and DisturbanceScale A.3.2 for Distraction and Disturbance

FIG. 2 Scale A.3.2 for Distraction and Disturbance (continued)

Scale A.3.2 for Distraction and DisturbanceScale A.3.2 for Distraction and Disturbance

FIG. 3 Scale A.3.3 for Vibration

Scale A.3.3 for VibrationScale A.3.3 for Vibration

FIG. 4 Scale A.3.4 for Lighting and Glare

Scale A.3.4 for Lighting and GlareScale A.3.4 for Lighting and Glare

FIG. 4 Scale A.3.4 for Lighting and Glare (continued)

Scale A.3.4 for Lighting and GlareScale A.3.4 for Lighting and Glare

FIG. 5 Scale A.3.5 for Adjustment of Lighting by Occupants

Scale A.3.5 for Adjustment of Lighting by OccupantsScale A.3.5 for Adjustment of Lighting by Occupants

FIG. 5 Scale A.3.5 for Adjustment of Lighting by Occupants (continued)

Scale A.3.5 for Adjustment of Lighting by OccupantsScale A.3.5 for Adjustment of Lighting by Occupants

FIG. 6 Scale A.3.6 for Distant and Outside Views

Scale A.3.6 for Distant and Outside ViewsScale A.3.6 for Distant and Outside Views

1.3 The entries in the Facility Rating Scale (see Figs. 1-6) are indicative and not comprehensive. They are for quick scanning to estimate approximately, quickly, and economically, how well an office facility is likely to meet the needs of one or another type of occupant group over time. The entries are not for measuring, knowing, or evaluating how an office facility is performing.

1.4 This classification can be used to estimate the level of serviceability of an existing facility. It can also be used to estimate the serviceability of a facility that has been planned but not yet built, such as one for which single-line drawings and outline specifications have been prep

More ASTM standard pdf

ASTM B413-97a(2003)

ASTM B413-97a(2003)

Standard Specification for Refined Silver

$26.00 $52.00

ASTM D4101-03b

ASTM D4101-03b

Standard Specification for Polypropylene Injection and Extrusion Materials

$33.00 $67.00

ASTM A738/A738M-03a

ASTM A738/A738M-03a

Standard Specification for Pressure Vessel Plates, Heat-Treated, Carbon-Manganese-Silicon Steel, for Moderate and Lower Temperature Service

$26.00 $52.00

ASTM B413-97a(2003)

ASTM B413-97a(2003)

Standard Specification for Refined Silver

$26.00 $52.00