1.1 These test methods cover fire-test-response.
1.2 These fire-test-response test methods provide information on the temperatures recorded on the electrical system component within a fire-resistive barrier system during the period of exposure.
1.3 This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products, or assemblies under actual fire conditions.
1.4 Potentially important factors and fire characteristics not addressed by these test methods include, but are not limited to:
1.4.1 The performance of the fire-resistive barrier system constructed with components other than those tested.
1.4.2 An evaluation of the functionality of the electrical system within the fire-resistive barrier system.
1.4.3 An evaluation of the ampacity of the electrical system within the fire-resistive barrier system.
1.4.4 An evaluation of the smoke, toxic gases, corrosivity, or other products of heating.
1.4.5 A measurement of the flame spread characteristics over the surface of the fire-resistive barrier system.
1.4.6 An evaluation of through-penetration sealing methods.
1.4.7 Combustibility of materials in the fire-resistive barrier system or of the electrical system components.
1.4.8 The need for supports beyond those normally required.
1.4.9 Environmental conditions in the area of service.
1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
1.7 Fire testing is inherently hazardous. Adequate safeguards for personnel and property shall be employed in conducting these tests.
Standard Test Method for Chemical Resistance of "Fiberglass" (Glass-Fiber-Reinforced Thermosetting-Resin) Pipe in a Deflected Condition
$30.00 $60.00
Standard Test Method for Determining Modulus, Tear and Adhesion Properties of Precured Elastomeric Joint Sealants
$29.00 $58.00
Standard Specification for Mercury-in-Glass, Maximum Self-Registering Clinical Thermometers
Standard Test Method for Detecting Detrimental Phases in Lean Duplex Austenitic/Ferritic Stainless Steels
$32.00 $65.00