• ASTM E1998-99

ASTM E1998-99

Standard Guide for Assessing Depressurization-Induced Backdrafting and Spillage from Vented Combustion Appliances

ASTM International, 01/10/1999

Publisher: ASTM

File Format: PDF

$34.00$69.00


Published:10/01/1999

Pages:13

File Size:1 file , 110 KB

Note:This product is unavailable in Russia, Ukraine, Belarus

1.1 This guide describes and compares different methods for assessing the potential for, or existence of, depressurization-induced backdrafting and spillage from vented residential combustion appliances.

1.2 Assessment of depressurization-induced backdrafting and spillage is conducted under either induced depressurization or natural conditions.

1.3 Residential vented combustion appliances addressed in this guide include hot water heaters and furnace. This guide also is applicable to boilers.

1.4 The methods given in this guide are applicable to Category I (draft-hood and induced-fan equipped) furnaces. The guide does not apply to Category III (power-vent equipped) or Category IV (direct-vent) furnaces.

1.5 The methods in this guide are not intended to identify backdrafting or spillage due to vent blockage or heat-exchanger leakage.

1.6 This guide is not intended to provide a basis for determining compliance with code requirements on appliance and venting installation, but does include a visual assessment of the installation. This assessment may indicate the need for thorough inspection by a qualified technician.

1.7 Users of the methods in this guide should be familiar with combustion appliance operation and with making house-tightness measurements using a blower door. Some methods described in this guide require familiarity with differential-pressure measurements and use of computer-based data-logging equipment.

1.8 This guide does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Carbon monoxide (CO) exposure or flame roll-out may occur when performing certain procedures given in this guide. See Section 7, for precautions that must be taken in conducting such procedures.

More ASTM standard pdf

ASTM E547-00(2016)

ASTM E547-00(2016)

Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Cyclic Static Air Pressure Difference

$24.00 $48.00

ASTM A821/A821M-15

ASTM A821/A821M-15

Standard Specification for Steel Wire, Hard-Drawn for Prestressed Concrete Tanks

$27.00 $54.00

ASTM D4366-16

ASTM D4366-16

Standard Test Methods for Hardness of Organic Coatings by Pendulum Damping Tests

$31.00 $62.00

ASTM C1296-95

ASTM C1296-95

Standard Test Method for Determination of Sulfur in Uranium Oxides and Uranyl Nitrate Solutions by X-Ray Fluorescence (XRF)

$27.00 $54.00