• ASTM E243-13

ASTM E243-13

Standard Practice for Electromagnetic (Eddy Current) Examination of Copper and Copper-Alloy Tubes

ASTM International, 12/01/2013

Publisher: ASTM

File Format: PDF

$30.00$60.00


Published:01/12/2013

Pages:6

File Size:1 file , 100 KB

Note:This product is unavailable in Russia, Ukraine, Belarus

1.1 This practice2 covers the procedures that shall be followed in eddy current examination of copper and copper-alloy tubes for detecting discontinuities of a severity likely to cause failure of the tube. These procedures are applicable for tubes with outside diameters to 31/8 in. (79.4 mm), inclusive, and wall thicknesses from 0.017 in. (0.432 mm) to 0.120 in. (3.04 mm), inclusive, or as otherwise stated in ASTM product specifications; or by other users of this practice. These procedures may be used for tubes beyond the size range recommended, upon contractual agreement between the purchaser and the manufacturer.

1.2 The procedures described in this practice are based on methods making use of encircling annular examination coil systems.

1.3 Units-The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

Note 1-This practice may be used as a guideline for the examination, by means of internal probe examination coil systems, of installations using tubular products where the outer surface of the tube is not accessible. For such applications, the technical differences associated with the use of internal probe coils should be recognized and accommodated. The effect of foreign materials on the tube surface and signals due to tube supports are typical of the factors that must be considered. See E690 for additional details regarding the in-situ examinations using internal probes.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

More ASTM standard pdf

ASTM F1983-14

ASTM F1983-14

Standard Practice for Assessment of Selected Tissue Effects of Absorbable Biomaterials for Implant Applications

$34.00 $68.00

ASTM E112-10

ASTM E112-10

Standard Test Methods for Determining Average Grain Size

$43.00 $86.00

ASTM D5230-14

ASTM D5230-14

Standard Test Method for Carbon Black -- Automated Individual Pellet Hardness

$30.00 $60.00

ASTM F1055-98e1

ASTM F1055-98e1

Standard Specification for Electrofusion Type Polyethylene Fittings for Outside Diameter Controlled Polyethylene Pipe and Tubing

$29.00 $58.00