• ASTM E2446-15

ASTM E2446-15

Standard Practice for Manufacturing Characterization of Computed Radiography Systems

ASTM International, 07/01/2015

Publisher: ASTM

File Format: PDF

$34.00$69.00


Published:01/07/2015

Pages:14

File Size:1 file , 970 KB

Note:This product is unavailable in Russia, Ukraine, Belarus

1.1 This practice describes the manufacturing characterization of computed radiography (CR) systems, consisting of a particular phosphor imaging plate (IP), scanner, software, and an image display monitor, in combination with specified metal screens for industrial radiography.

1.2 The practice defines system tests to be used to characterize the systems of different suppliers and make them comparable for users.

1.3 This practice is intended for use by manufacturers of CR systems or certification agencies to provide quantitative results of CR system characteristics for nondestructive testing (NDT) user or purchaser consumption. Some of these tests require specialized test phantoms to ensure consistency of results among suppliers or manufacturers. These tests are not intended for users to complete, nor are they intended for long term stability tracking and lifetime measurements. However, they may be used for this purpose, if so desired.

1.4 The CR system performance is described by the basic spatial resolution, contrast, signal and noise parameters, and the equivalent penetrameter sensitivity (EPS). Some of these parameters are used to compare with DDA characterization and film characterization data (see Practice E2597 and Test Method E1815).

Note 1: For film system characterization, the signal is represented by the optical density of 2 (above fog and base) and the noise as granularity. The signal-to-noise ratio is normalized by the aperture (similar to the basic spatial resolution) of the system and is part of characterization. This normalization is given by the scanning circular aperture of 100 µm of the micro-photometer, which is defined in Test Method E1815 for film system characterization.

1.5 The measurement of CR systems in this practice is restricted to a selected radiation quality to simplify the procedure. The properties of CR systems will change with radiation energy but not the ranking of CR system performance. Users of this practice may carry out the tests at different or additional radiation qualities (X-ray or gamma ray) if required.

1.6 The values stated in SI are to be regarded as the standard.

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.

More ASTM standard pdf

ASTM D5349-95

ASTM D5349-95

Standard Test Method for Determination of the Moisture and Volatile Content of Sulfonated and Sulfated Oils by Hot-Plate Method

$25.00 $50.00

ASTM E211-82(2010)

ASTM E211-82(2010)

Standard Specification for Cover Glasses and Glass Slides for Use in Microscopy

$26.00 $52.00

ASTM D3524-14

ASTM D3524-14

Standard Test Method for Diesel Fuel Diluent in Used Diesel Engine Oils by Gas Chromatography

$31.00 $62.00

ASTM E210-63(2010)

ASTM E210-63(2010)

Standard Specification for Microscope Objective Thread

$26.00 $52.00