• ASTM E2912-13

ASTM E2912-13

Standard Test Method for Fire Test of Non-Mechanical Fire Dampers Used in Vented Construction

ASTM International, 07/01/2013

Publisher: ASTM

File Format: PDF

$32.00$65.00


Published:01/07/2013

Pages:20

File Size:1 file , 1.2 MB

Note:This product is unavailable in Russia, Ukraine, Belarus

Note 1-Non-mechanical fire dampers can be used in vented construction. Vented constructions may be parts of buildings including walls, floors, ceilings and concealed spaces and cavities used for air transfer and to allow ventilation in structures without ductwork. Non-mechanical fire dampers can be located adjacent to combustible construction or materials and situated in exposed or concealed locations, or both. Unlike typical fire resistive assemblies, vented construction uses non-mechanical fire dampers to allow air transfer without the use of ducts. Resistance to flame, radiation, and hot gases may be requirements when direct flame impingement is a credible risk, or when no penetration of flames is required by the authority having jurisdiction, or both. The proposed test method provides procedures that enable an assessment of this direct flame impingement on non-mechanical fire dampers. This test method does not alter any requirements for non-mechanical fire dampers used in fire resistance rated construction and assemblies.
Note 3-There are currently no published test methods (nationally or internationally) that address the application of sudden direct flame impingement on non-mechanical fire dampers used in vented construction. In the European Union (EU), CEN (European Committee for Standardization) has very recently started a work item to address reaction to sudden direct flame impingement on non-mechanical fire dampers. Also, in the EU, some countries have used large scale tests with 5MW fire exposures to assess test specimens' reactions to sudden direct flame impingement as part of the entire building construction. Standard time-temperature curves used to control gas-fired furnaces do not ensure a sudden direct flame impingement on the test specimen, which this test method is designed to do. A post flashover condition, the spontaneous combustion of materials, ignition of a highly combustible material acting as the source of the fire (for example, stored cleaning solutions or fuels) or the location of materials can create a fire scenario resulting in a sudden direct flame impingement.

More ASTM standard pdf

ASTM E1519-01

ASTM E1519-01

Standard Terminology Relating to Agricultural Tank Mix Adjuvants

$25.00 $50.00

ASTM E609-00

ASTM E609-00

Standard Terminology Relating to Pesticides

$26.00 $52.00

ASTM D5746-98(2002)

ASTM D5746-98(2002)

Standard Classification of Environmental Condition of Property Area Types for Defense Base Closure and Realignment Facilities

$30.00 $60.00

ASTM E2758-15

ASTM E2758-15

Standard Guide for Selection and Use of Wideband, Low Temperature Infrared Thermometers

$32.00 $65.00