• ASTM E398-03(2009)e1

ASTM E398-03(2009)e1

Standard Test Method for Water Vapor Transmission Rate of Sheet Materials Using Dynamic Relative Humidity Measurement

ASTM International, 05/01/2009

Publisher: ASTM

File Format: PDF

$26.00$52.00


Published:01/05/2009

Pages:4

File Size:1 file , 83 KB

Note:This product is unavailable in Russia, Ukraine, Belarus

1.1 This test method covers dynamic evaluation of the rate of transfer of water vapor through a flexible barrier material and allows conversion to the generally recognized units of water vapor transmission (WVT) as obtained by various other test methods including the gravimetric method described in Test Methods E 96/E 96M.

1.2 Limitations - This test method is limited to flexible barrier sheet materials composed of either completely hydrophobic materials, or combinations of hydrophobic and hydrophilic materials having at least one surface that is hydrophobic.

1.3 The minimum test value obtained by this test method is limited by the leakage of water vapor past the clamping seals of the test instrument. A reasonable value may be approximately 0.01 g/24 h·m² for any WVTR method including the desiccant procedure of Test Methods E 96/E 96M at 37.8°C, and 90 % relative humidity. This limit can be checked for each instrument with an impervious specimen such as aluminum foil. Calibration procedures can compensate for the leakage rate if so stated.

1.4 This test method is not suitable for referee testing at this time, but is suitable for control testing and material comparison.

1.5 Several other ASTM test methods are available to test a similar property. This test method is unique in that it closely duplicates typical product storage where a transfer of moisture from a package into the environment is allowed to proceed without constantly sweeping the environmental side with dry gas. Methods with constantly swept dry sides include Test Methods F 1249, F 372, and F 1770.

1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

More ASTM standard pdf

ASTM D7905/D7905M-19e1

ASTM D7905/D7905M-19e1

Standard Test Method for Determination of the Mode II Interlaminar Fracture Toughness of Unidirectional Fiber-Reinforced Polymer Matrix Composites

$28.00 $56.00

ASTM E1270-88(2014)

ASTM E1270-88(2014)

Standard Test Method for Equal Arm Balances (Withdrawn 2021)

$31.00 $62.00

ASTM C506M-16a

ASTM C506M-16a

Standard Specification for Reinforced Concrete Arch Culvert, Storm Drain, and Sewer Pipe (Metric)

$29.00 $58.00

ASTM D4188-17

ASTM D4188-17

Standard Practice for Performing Pressure In-Line Coagulation-Flocculation-Filtration Test in Water

$21.00 $42.00