Your shopping cart is empty!
ASTM International, 07/01/2011
Publisher: ASTM
File Format: PDF
$30.00$60.00
Published:01/07/2011
Pages:4
File Size:1 file , 98 KB
Note:This product is unavailable in Russia, Ukraine, Belarus
1.1 This practice covers procedures for testing and locating the sources of gas leaking at the rate of 1 × 10−8 Pa m³/s (1 × 10−9 Std cm 3/s) or greater. The test may be conducted on any object to be tested that can be evacuated and to the other side of which helium or other tracer gas may be applied.
1.2 Three test methods are described:
1.2.1 Test Method A - For the object under test capable of being evacuated, but having no inherent pumping capability.
1.2.2 Test Method B - For the object under test with integral pumping capability.
1.2.3 Test Method C - For the object under test as in Test Method B, in which the vacuum pumps of the object under test replace those normally used in the leak detector.
1.3 Units - The values stated in either SI or std-cc/sec units are to be regarded separately as standard. The values stated in each system may not be exact equivalents: therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Standard Specification for Industrial Chimney Lining Brick
$30.00 $60.00
Standard Test Method for Hydrogen Sulfide in Natural Gas Using Length-of-Stain Detector Tubes
$27.00 $54.00
Standard Test Methods for Water in Halogenated Organic Solvents and Their Admixtures
$32.00 $64.00
Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model
$34.00 $69.00