• ASTM E745-80(2003)

ASTM E745-80(2003)

Standard Practices for Simulated Service Testing for Corrosion of Metallic Containment Materials for Use With Heat-Transfer Fluids in Solar Heating and Cooling Systems

ASTM International, 05/30/1980

Publisher: ASTM

File Format: PDF

$30.00$60.00


Published:30/05/1980

Pages:8

File Size:1 file , 110 KB

Note:This product is unavailable in Russia, Ukraine, Belarus

1.1 These practices cover test procedures simulating field service for evaluating the performance under corrosive conditions of metallic containment materials in solar heating and cooling systems. All test results relate to the performance of the metallic containment material only as a part of a metal/fluid pair. Performance in these test procedures, taken by itself, does not necessarily constitute an adequate basis for acceptance or rejection of a particular metal/fluid pair in solar heating and cooling systems, either in general or in a particular design.

1.2 These practices describe test procedures used to evaluate the resistance to deterioration of metallic containment materials in the several conditions that may occur in operation of solar heating and cooling systems. These conditions include: (1) operating full flow; (2) stagnant empty vented; ( 3) stagnant, closed to atmosphere, non-draindown; and ( 4) stagnant, closed to atmosphere, draindown.

1.3 The recommended practices cover the following three tests:

1.3.1 Practice ALaboratory Exposure Test for Coupon Specimens.

1.3.2 Practice BLaboratory Exposure Test of Components or Subcomponents.

1.3.3 Practice CField Exposure Test of Components or Subcomponents.

1.4 Practice A provides a laboratory simulation of various operating conditions of solar heating and cooling systems. It utilizes coupon test specimens and does not provide for heating of the fluid by the containment material. Practice B provides a laboratory simulation of various operating conditions of a solar heating and cooling system utilizing a component or a simulated subcomponent construction, and does provide for heating of the fluid by the containment material. Practice C provides a field simulation of various operating conditions of solar heating and cooling systems utilizing a component or a simulated subcomponent construction. It utilizes controlled schedules of operation in a field test.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For a specific safety precaution statement see Section 6.

More ASTM standard pdf

ASTM D2916-09(2023)

ASTM D2916-09(2023)

Standard Specification for Isophorone

$25.00 $50.00

ASTM D4739-23

ASTM D4739-23

Standard Test Method for Base Number Determination by Potentiometric Hydrochloric Acid Titration

$28.00 $57.00

ASTM E3141/E3141M-23

ASTM E3141/E3141M-23

Standard Test Method for Ballistic Resistant Shields for Law Enforcement

$28.00 $57.00

ASTM D6241-22a

ASTM D6241-22a

Standard Test Method for Measuring Static Puncture Strength of Geotextiles and Geosynthetic-Related Products Using a 50 mm Probe

$28.00 $57.00