• ASTM E970-10

ASTM E970-10

Standard Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using a Radiant Heat Energy Source

ASTM International, 07/01/2010

Publisher: ASTM

File Format: PDF

$32.00$65.00


Published:01/07/2010

Pages:12

File Size:1 file , 270 KB

Note:This product is unavailable in Russia, Ukraine, Belarus

1.1 This fire-test-response standard describes a procedure for measuring the critical radiant flux of exposed attic floor insulation subjected to a flaming ignition source in a graded radiant heat energy environment in a test chamber. The specimen is any attic floor insulation. This test method is not applicable to those insulations that melt or shrink away when exposed to the radiant heat energy environment or the pilot burner.

1.2 This fire-test-response standard measures the critical radiant flux at the point at which the flame advances the farthest. It provides a basis for estimating one aspect of fire exposure behavior for exposed attic floor insulation. The imposed radiant flux simulates the thermal radiation levels likely to impinge on the floors of attics whose upper surfaces are heated by the sun through the roof or by flames from an incidental fire in the attic. This fire-test-response standard was developed to simulate an important fire exposure component of fires that develop in attics, but is not intended for use in estimating flame spread behavior of insulation installed other than on the attic floor.

1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only.

1.4 The text of this standard references notes and footnotes that provide explanatory information. These notes and footnotes, excluding those in tables and figures, shall not be considered as requirements of this standard.

1.5 This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products, or assemblies under actual fire conditions.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

1.7 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.

More ASTM standard pdf

ASTM E1194-07

ASTM E1194-07

Standard Test Method for Vapor Pressure (Withdrawn 2013)

$29.00 $58.00

ASTM F2783-17

ASTM F2783-17

Standard Practice for Design, Manufacture, Operation, Maintenance, and Inspection of Amusement Rides and Devices, in Canada

$34.00 $69.00

ASTM B152/B152M-06

ASTM B152/B152M-06

Standard Specification for Copper Sheet, Strip, Plate, and Rolled Bar

$30.00 $60.00

ASTM D1485-07(2015)

ASTM D1485-07(2015)

Standard Practice for Rubber from Natural Sources-Sampling and Sample Preparation

$26.00 $52.00