1.1 This guide presents background and guidelines for establishing an appropriate sequence of tests and data analysis procedures for determining the ionizing radiation (total dose) harness of microelectronic devices for dose rates below 300 rd(SiO2)/s. These tests and analysis will be appropriate to assist in the determination of the ability of the devices under test to meet specific hardness requirements or to evaluate the parts for use in a range of radiation environments.

1.2 The methods and guidelines presented will be applicable to characterization, qualification, and lot acceptance of silicon-based MOS and bipolar discrete devices and integrated circuits. They will be appropriate for treatment of the effects of electron and photon irradiation.

1.3 This guide provides a framework for choosing a test sequence based on general characteristics of the parts to be tested and the radiation hardness requirements or goals for these parts.

1.4 This guide provides for tradeoffs between minimizing the conservative nature of the testing method and minimizing the required testing effort.

1.5 Determination of an effective and economical hardness test typically will require several kinds of decisions. A partial enumeration of the decisions that typically must be made is as follows:

1.5.1 Determination of the Need to Perform Device Characterization-For some cases it may be more appropriate to adopt some kind of worst case testing scheme that does not require device characterization. For other cases it may be most effective to determine the effect of dose-rate on the radiation sensitivity of a device. As necessary, the appropriate level of detail of such a characterization also must be determined.

1.5.2 Determination of an Effective Strategy for Minimizing the Effects of Irradiation Dose Rate on the Test Result-The results of radiation testing on some types of devices are relatively insensitive to the dose rate of the radiation applied in the test. In constrast, many MOS devices and some bipolar devices have a significant sensitivity to dose rate. Several different strategies for managing the dose rate sensitivity of test results will be discussed.

1.5.3 Choice of an Effective Test Methodology-The selection of effective test methodologies will be discussed.

1.6 Low Dose Requirements-Hardness testing of MOS and bipolar microelectronic devices for the purpose of qualification or lot acceptance is not neceassary when the required hardness is 100 rd(SiO2) or lower.

1.7 Sources-This guide will cover effects due to device testing using irradiation from photon sources, such as 60Co y irradiators, 137Cs y irradiators, and low energy (approximately 10 keV) X-ray sources. Other sources of test radiation such as linacs, Van de Graaff sources, Dymnamitrons, SEM's and flash X-ray sources occasionally are used but are outside the scope of this guide.

1.8 Displacement damage effects are outside the scope of this guide, as well.

1.9 The values stated in SI units are to be regarded as the standard.

More ASTM standard pdf

ASTM E1275-98e1

ASTM E1275-98e1

Standard Practice for Use of a Radiochromic Film Dosimetry System (Withdrawn 2002)

$29.00 $58.00

ASTM C1635-14

ASTM C1635-14

Standard Test Method to Evaluate Adhesion/Cohesion Properties of a Sealant at Fixed Extension

$26.00 $52.00

ASTM F1561-03(2014)

ASTM F1561-03(2014)

Standard Performance Requirements for Plastic Chairs for Outdoor Use (Withdrawn 2019)

$26.00 $52.00

ASTM F2972-14e1

ASTM F2972-14e1

Standard Specification for Light Sport Aircraft Manufacturer's Quality Assurance System

$25.00 $50.00