Your shopping cart is empty!
ASTM International, 03/01/2017
Publisher: ASTM
File Format: PDF
$36.00$72.00
Published:01/03/2017
Pages:17
File Size:1 file , 290 KB
Note:This product is unavailable in Russia, Ukraine, Belarus
1.1 This test method may be used to determine the initial, fractional, filtration efficiency of household and commercial canister (tank-type), stick, hand-held, upright, and utility vacuum cleaner systems.
1.1.1 Water-filtration vacuum cleaners which do not utilize a replaceable dry media filter located between the water-based filter and cleaning air exhaust are not included in this test method. It has been determined that the exhaust of these vacuum cleaners is not compatible with the specified discrete particle counter (DPC) procedure.
1.2 The initial, fractional, filtration efficiencies of the entire vacuum cleaner system, at six discrete particle sizes (0.3, 0.5, 0.7, 1.0, 2.0, and >3 μm), is derived by counting upstream challenge particles and the constituent of downstream particles while the vacuum cleaner system is being operated in a stationary test condition.
1.3 The vacuum cleaner system is tested at the nozzle with the normal airflow rate produced by restricting the inlet to the nozzle adapter with the 11/4-in. orifice.
1.4 The vacuum cleaner system is tested with a new filter(s) installed, and with no preliminary dust loading. The fractional efficiencies determined by this test method shall be considered initial system filtration efficiencies. The filters are not changed between test runs on the same cleaner.
1.5 Neutralized potassium chloride (KCl) is used as the challenge media in this test method.
1.6 One or two particle counters may be used to satisfy the requirements of this test method. If using one counter, flow control is required to switch between sampling the upstream and downstream air sampling probes.
1.7 To efficiently utilize this test method, automated test equipment and computer automation is recommended.
1.8 Different sampling parameters, flow rates, and so forth, for the specific applications of the equipment and test procedure may provide equivalent results. It is beyond the scope of this test method to define those various possibilities.
1.9 This test method is limited to the test apparatus, or its equivalent, as described in this document.
1.10 This test method is not intended or designed to provide any measure of the health effects or medical aspects of vacuum cleaning.
1.11 This test method is not intended or designed to determine the integrity of HEPA filtration assemblies used in vacuum cleaner systems employed in nuclear and defense facilities.
1.12 The inch-pound system of units is used in this test method, except for the common usage of the micrometer, μm, for the description of particle size which is a SI unit.
1.13 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Standard Guide for Training First Responders Who Practice in Wilderness, Delayed, or Prolonged Transport Settings
$25.00 $50.00
Standard Practice for Use of Chemical-Resistant Sulfur Mortar
$26.00 $52.00
Standard Practice for Determining Safe Current Pulse-Operating Regions for Metallization on Semiconductor Components [Metric]
$29.00 $58.00
Standard Test Method for Determining Current Carrying Capacity of a Conductor as Part of a Membrane Switch Circuit