ASTM F1983-99(2008)

Standard Practice for Assessment of Compatibility of Absorbable/Resorbable Biomaterials for Implant Applications

ASTM International, 08/01/2008

Publisher: ASTM

File Format: PDF

$29.00$58.00


Published:01/08/2008

Pages:5

File Size:1 file , 81 KB

Note:This product is unavailable in Russia, Ukraine, Belarus

1.1 This practice provides experimental protocols for biological assays of tissue reactions to absorbable/resorbable biomaterials for implant applications. This practice applies only to resorbable/absorbable materials with projected clinical applications in which the materials will reside in bone or soft tissue longer than 30 days and less than three years. Other standards with designated implantation times are available to address the shorter time periods. Careful consideration should be given to the appropriateness of this practice for slowly degrading materials that will remain for longer than three years. It is anticipated that the tissue response to degrading biomaterials will be different from the response to nonresorbable materials. In many cases, a chronic inflammatory response may be observed during the degradation phase, but the local histology should return to normal after degradation; therefore, the minimal tissue response usually equated with "biocompatibility" may require long implantations.

1.2 The time period for implant degradation will vary depending on chemical composition and implant size; therefore, the implantation times for examination of tissue response will be linked to the rate of resorption. No single implantation time is indicated in this practice.

1.3 These protocols assess the effects of the material on the animal tissue in which it is implanted. The experimental protocols do not fully assess systemic toxicity, carcinogenicity, teratogenicity, or mutagenicity of the material. Other standards are available to address these issues.

1.4 To maximize use of the animals in the study protocol, all toxicological findings should be recorded. There are some aspects of systemic toxicity, including effects of degradation products on the target organs, that can be addressed with this practice, and these effects should be documented fully.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

More ASTM standard pdf

ASTM A934/A934M-16

ASTM A934/A934M-16

Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars

$32.00 $65.00

ASTM D2519-07

ASTM D2519-07

Standard Test Method for Bond Strength of Electrical Insulating Varnishes by the Helical Coil Test

$26.00 $52.00

ASTM E1742-00

ASTM E1742-00

Standard Practice for Radiographic Examination

$32.00 $65.00

ASTM B8-11

ASTM B8-11

Standard Specification for Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard, or Soft

$30.00 $60.00