• ASTM F1983-99(2008)

ASTM F1983-99(2008)

Standard Practice for Assessment of Compatibility of Absorbable/Resorbable Biomaterials for Implant Applications

ASTM International, 08/01/2008

Publisher: ASTM

File Format: PDF

$29.00$58.00


Published:01/08/2008

Pages:5

File Size:1 file , 81 KB

Note:This product is unavailable in Russia, Ukraine, Belarus

1.1 This practice provides experimental protocols for biological assays of tissue reactions to absorbable/resorbable biomaterials for implant applications. This practice applies only to resorbable/absorbable materials with projected clinical applications in which the materials will reside in bone or soft tissue longer than 30 days and less than three years. Other standards with designated implantation times are available to address the shorter time periods. Careful consideration should be given to the appropriateness of this practice for slowly degrading materials that will remain for longer than three years. It is anticipated that the tissue response to degrading biomaterials will be different from the response to nonresorbable materials. In many cases, a chronic inflammatory response may be observed during the degradation phase, but the local histology should return to normal after degradation; therefore, the minimal tissue response usually equated with "biocompatibility" may require long implantations.

1.2 The time period for implant degradation will vary depending on chemical composition and implant size; therefore, the implantation times for examination of tissue response will be linked to the rate of resorption. No single implantation time is indicated in this practice.

1.3 These protocols assess the effects of the material on the animal tissue in which it is implanted. The experimental protocols do not fully assess systemic toxicity, carcinogenicity, teratogenicity, or mutagenicity of the material. Other standards are available to address these issues.

1.4 To maximize use of the animals in the study protocol, all toxicological findings should be recorded. There are some aspects of systemic toxicity, including effects of degradation products on the target organs, that can be addressed with this practice, and these effects should be documented fully.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

More ASTM standard pdf

ASTM F900-94(2000)

ASTM F900-94(2000)

Standard Specification for Industrial and Commercial Swing Gates

$25.00 $50.00

ASTM F679-00a

ASTM F679-00a

Standard Specification for Poly(Vinyl Chloride) (PVC) Large-Diameter Plastic Gravity Sewer Pipe and Fittings

$29.00 $58.00

ASTM D3266-91(2000)e1

ASTM D3266-91(2000)e1

Standard Test Method for Automated Separation and Collection of Particulate and Acidic Gaseous Fluoride in the Atmosphere (Double Paper Tape Sampler Method)

$29.00 $58.00

ASTM D3944-88(2000)

ASTM D3944-88(2000)

Standard Test Method for Solidification Point of Petroleum Wax

$26.00 $52.00