• ASTM F561-05a

ASTM F561-05a

Standard Practice for Retrieval and Analysis of Medical Devices, and Associated Tissues and Fluids

ASTM International, 10/01/2005

Publisher: ASTM

File Format: PDF

$32.00$65.00


Published:01/10/2005

Pages:16

File Size:1 file , 180 KB

Note:This product is unavailable in Russia, Ukraine, Belarus

1.1 This practice covers recommendations for the retrieval, handling, and analysis of implanted medical devices and associated specimens that are removed from patients during revision surgery, at postmortem, or as part of animal studies. This practice can also be used for analysis of specimens and lubrication fluids from in vitro wear tests and joint simulators. The aim is to provide guidance in preventing damage to the associated specimens which could obscure the investigational results, and in gathering data at the proper time and circumstance to validate the study.

1.2 This practice offers guidelines for the analysis of retrieved implants to limit damage to them, and to allow comparisons between investigational results from different studies. The protocols are divided into three stages, where Stage I is the minimum non-destructive analysis, Stage II is more complete non-destructive analysis, and Stage III is destructive analysis. Standard protocols for the examination and collection of data are provided for specific types of materials in relation to their typical applications. For particular investigational programs, additional, more specific, protocols may be required. If special analytical techniques are employed, the appropriate handling procedures must be specified.

1.3 This practice recommendation should be applied in accordance with national regulations or legal requirements regarding the handling and analysis of retrieved implants and excised tissues, especially with regard to handling devices which may become involved in litigation, as per Practice E 860.

1.4 A significant portion of the information associated with a retrieved implant device is often at the device-tissue interface or in the tissues associated with the implant and related organ systems. Attention should be given to the handling of adjacent tissues, so as not to interfere with study of the particles in the adjacent tissue, a chemical analysis for the byproducts of degradation of the implant, or a study of the cellular response to the implant.

1.5 This standard may involve hazardous materials, operations, and equipment. As a precautionary measure, removed implants should be sterilized or minimally disinfected by an appropriate means that does not adversely affect the implant or the associated tissue that may be subject to subsequent analysis. A detailed discussion of precautions to be used in handling of human tissues can be found in ISO 12891-1. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

More ASTM standard pdf

ASTM D4273-23

ASTM D4273-23

Standard Test Method for Polyurethane Raw Materials: Determination of Primary Hydroxyl Content of Polyether Polyols

$28.00 $57.00

ASTM D6136/D6136M-15(2021)

ASTM D6136/D6136M-15(2021)

Standard Test Method for Kerosine Number of Unsaturated (Dry) Felt by Vacuum Method

$24.00 $48.00

ASTM D8164-21

ASTM D8164-21

Standard Guide for Digital Contact Thermometers for Petroleum Products, Liquid Fuels, and Lubricant Testing

$28.00 $57.00

ASTM D6493-11(2022)

ASTM D6493-11(2022)

Standard Test Methods for Softening Point of Hydrocarbon Resins and Rosin Based Resins by Automated Ring-and-Ball Apparatus

$28.00 $57.00