• ASTM G114-06

ASTM G114-06

Standard Practices for Evaluating the Age Resistance of Polymeric Materials Used in Oxygen Service

ASTM International, 06/15/2006

Publisher: ASTM

File Format: PDF

$29.00$58.00


Published:15/06/2006

Pages:5

File Size:1 file , 140 KB

Note:This product is unavailable in Russia, Ukraine, Belarus

1.1 These practices describe several procedures that are used to determine the age resistance of plastic, thermosetting, and elastomeric materials exposed to oxygen-containing media.

1.2 These practices address both established methods that have a foundation of experience and potential methods that have yet to be validated. The latter are included to promote research and later elaboration in this practice as methods of the former type.

1.3 The results of these practices may not give exact correlation with service performance since service conditions vary widely and may involve multiple factors. This practice may be used to evaluate materials on a laboratory comparison basis.

1.4 Three procedures are described for evaluating the age resistance of polymeric materials depending on application and information sought.

1.4.1 Procedure A: Natural AgingThis procedure is used to simulate the effect(s) of one or more service stressors on a materials oxygen resistance, and is suitable for evaluating materials that experience continuous or intermittent exposure to elevated temperature during service.

1.4.2 Procedure B: Accelerated Aging Comparative Oxygen ResistanceThis procedure is suitable for evaluating materials that are used in ambient temperature service, or at a temperature that is otherwise lower than the aging temperature, and is useful for developing oxygen compatibility rankings on a laboratory comparison basis.

1.4.3 Procedure C: Accelerated Aging Lifetime PredictionThis procedure is used to determine the relationship between aging temperature and predefined level property change, thereby allowing predictions to be made about the effect of prolonged service on oxidative degradation.

1.5 The values stated in SI units are to be regarded as the standard, however, all numerical values must also be cited in the systems in which they were actually measured.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Section 10.

More ASTM standard pdf

ASTM F3027-13

ASTM F3027-13

Standard Guide for Training of Personnel Operating in Mountainous Terrain (Mountain Endorsement)

$25.00 $50.00

ASTM E961-97(2008)

ASTM E961-97(2008)

Standard Specification for Blood Sedimentation Tube, Wintrobe, Glass, Reusable

$25.00 $50.00

ASTM D7348-13

ASTM D7348-13

Standard Test Methods for Loss on Ignition (LOI) of Solid Combustion Residues

$32.00 $64.00

ASTM E1404-94(2008)

ASTM E1404-94(2008)

Standard Specification for Laboratory Glass Conical Flasks

$25.00 $50.00