• ASTM G130-06

ASTM G130-06

Standard Test Method for Calibration of Narrow- and Broad-Band Ultraviolet Radiometers Using a Spectroradiometer

ASTM International, 06/01/2006

Publisher: ASTM

File Format: PDF

$29.00$58.00


Published:01/06/2006

Pages:6

File Size:1 file , 79 KB

Note:This product is unavailable in Russia, Ukraine, Belarus

1.1 This test method covers the calibration of ultraviolet light-measuring radiometers possessing either narrow- or broad-band spectral response distributions using either a scanning or a linear-diode-array spectroradiometer as the primary reference instrument. For transfer of calibration from radiometers calibrated by this test method to other instruments, Test Method E 824 should be used. Note 1 Special precautions must be taken when a diode-array spectroradiometer is employed in the calibration of filter radiometers having spectral response distributions below 320-nm wavelength. Such precautions are described in detail in subsequent sections of this test method.

1.2 This test method is limited to calibrations of radiometers against light sources that the radiometers will be used to measure during field use. Note 2 For example, an ultraviolet radiometer calibrated against natural sunlight cannot be employed to measure the total ultraviolet irradiance of a fluorescent ultraviolet lamp.

1.3 Calibrations performed using this test method may be against natural sunlight, Xenon-arc burners, metal halide burners, tungsten and tungsten-halogen lamps, fluorescent lamps, etc.

1.4 Radiometers that may be calibrated by this test method include narrow-, broad-, and wide-band ultraviolet radiometers, and narrow-, broad, and wide-band visible-region-only radiometers, or radiometers having wavelength response distributions that fall into both the ultraviolet and visible regions. Note 3 For purposes of this test method, narrow-band radiometers are those with 20 nm, broad-band radiometers are those with 20 nm 70 nm, and wide-band radiometers are those with 70 nm.

Note 4

For purposes of this test method, the ultraviolet region is defined as the region from 285 to 400-nm wavelength, and the visible region is defined as the region from 400 to 750-nm wavelength. The ultraviolet region is further defined as being either UV-A with radiation of wavelengths from 315 to 400 nm, or UV-B with radiation from 285 to 315-nm wavelength.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

More ASTM standard pdf

ASTM D1946-90(2015)e1

ASTM D1946-90(2015)e1

Standard Practice for Analysis of Reformed Gas by Gas Chromatography

$30.00 $60.00

ASTM D5540-13(2021)

ASTM D5540-13(2021)

Standard Practice for Flow Control and Temperature Control for On-Line Water Sampling and Analysis

$26.00 $52.00

ASTM C198-09(2019)

ASTM C198-09(2019)

Standard Test Method for Cold Bonding Strength of Refractory Mortar

$24.00 $48.00

ASTM D7578-18

ASTM D7578-18

Standard Guide for Calibration Requirements for Elemental Analysis of Petroleum Products and Lubricants

$33.00 $67.00