BS 6724:2016

Electric cables. Thermosetting insulated, armoured cables of rated voltages of 600/1 000 V and 1 900/3 300 V for fixed installations, having low emission of smoke and corrosive gases when affected by fire. Specification

BSI Group, 02/28/2017

Publisher: BS

File Format: PDF

$166.00$332.74


Published:28/02/2017

Pages:50

File Size:1 file , 1.5 MB

Note:This product is unavailable in Ukraine, Russia, Belarus

BS 6724:2016 specifies requirements for the construction and performance of thermosetting insulated, armoured cables of rated voltages of 600/1 000 V and 1 900/3 300 V, having low emission of smoke and corrosive gases when affected by fire.

NOTE 1 Other thermosetting insulated, armoured cables for voltages of 600/1 000 V and 1 900/3 300 V can be found in BS 5467, but these do not have low levels of emission of smoke and corrosive products under exposure to fire.


This British Standard is applicable to cables for use in fixed installations in industrial areas, buildings or similar applications.

This British Standard specifies requirements for the following types of cables:
  • 600/1 000 V cables, wire armoured and oversheathed having single-core, two-, three-, four- and five-core stranded copper conductor;
  • 600/1 000 V multicore auxiliary cables, wire armoured, and oversheathed, stranded copper conductor; and
  • 1 900/3 300 V cables, wire armoured and oversheathed, having single-core or three-core stranded copper conductor.
This British Standard is applicable to cables that are designed for a maximum sustained conductor temperature of 90 °C and for a maximum short-circuit conductor temperature of 250 °C (for a maximum of 5 s).

NOTE 2 Limitation on the temperature of the cables may be imposed in situations where they might be touched or where they could touch other materials.

NOTE 3 Annex A gives a guide to the use and installation of cables, Annex B gives armour wire tests, Annex C gives a compatibility test, Annex D gives an abrasion resistance test, Annex E gives an insulation resistance constant test on oversheath, Annex F gives the resistance of conductor and armour, Annex G gives the gross cross-sectional area of armour, Annex H gives a test for shrinkage of oversheath on cable, Annex I gives guidance on type tests and Annex J gives the standard United Kingdom reference codes.



Cross References:
BS 7655-1.2
BS 7655-1.3
BS 7655-6.1
BS EN 10244-2:2009
BS EN 50363-5
BS EN 50395
BS EN 50396
BS EN 60228
BS EN 60229
BS EN 60332-1-2:2004+A1:2015
BS EN 60332-3-24:2009
BS EN 60754-1
BS EN 60811-401
BS EN 60811-501
BS EN 60811-502
BS EN 61034-2
BS EN 62230
BS EN ISO 6892-1
IEC 60050-461
BS 5467
BS 7671:2008+A3:2015
BS 8512
BS 8573:2012
BS EN 50262
BS EN 50393
BS EN 60079-14
BS EN 61914
BS EN 62275
BS EN 62444
IEC 60183
Electricity Safety, Quality and Continuity Regulations
2002


Replaces BS 6724:1997+A3:2008 which remains current

All current amendments available at time of purchase are included with the purchase of this document.

More BS standard pdf

BS 1646-4:1984

BS 1646-4:1984

Symbolic representation for process measurement control functions and instrumentation-Specification for basic symbols for process computer, interface and shared display/control functions

$90.00 $180.34

BS 3408:1977

BS 3408:1977

Specification for tarpaulins

$90.00 $180.34

BS 5086-2:1984

BS 5086-2:1984

Analysis of butter-Method for determination of water, solids-not-fat and fat contents (reference method)

$125.00 $251.46

BS 6407-2:1984

BS 6407-2:1984

Cage pallets for retail use-Guide to the safe handling and use of collapsible cage pallets rated at 300 kg

$76.00 $152.40