• CSA ANSI/CSA America FC 3-2004 (R2021)

CSA ANSI/CSA America FC 3-2004 (R2021)

Portable Fuel Cell Power Systems

CSA Group, 10/22/2004

Publisher: CSA

File Format: PDF

$371.00$742.00


Published:22/10/2004

Pages:122

File Size:1 file , 1.2 MB

Note:This product is unavailable in Russia, Ukraine, Belarus

Scope
1.1.1 This Standard applies to ac and dc type portable fuel cell power systems, with a rated output voltage not exceeding 600 V, for commercial, industrial, and residential indoor and
outdoor use in non-hazardous locations, in accordance with the Rules of the National Electric Code, ANSI/NFPA 70.
1.1.2 This Standard does not apply to portable fuel cell power systems that are
a. Permanently connected (stationary) to either fuel or electric supply;
b. Designed to export power to the grid;
c. Replacement fuel cell power units for appliances; or
d. Fuel cell systems for propulsion.
1.1.3 Fuels considered within the scope of this standard are:
a. Natural Gas;
b. Liquefied Petroleum / Propane Gases;
c. Liquid Alcohols e.g. Methanol, Ethanol;
d. Gasoline;
e. Diesel;
f. Kerosene;
g. Hydrogen;
h. Chemical Hydrides; and
i. Metallic.
1.1.4 The overall design of a portable fuel cell power system anticipated by this standard shall form an assembly of integrated systems, as necessary, intended to perform designated
functions, as follows:
a. Fuel Processing System - meters and processes incoming fuel supply for use within the portable fuel cell power system.

b. Air Processing System - meters, conditions, processes and may pressurize (blowers or turbochargers) incoming air supply for use within the portable fuel cell power system.
c. Thermal Management System - provides cooling and heat rejection to maintain thermal equilibrium within the portable fuel cell power system and may provide for recovery of excess heat and assist in heating the portable fuel cell power system
during startup.
d. Electrical System - conditions output power of the fuel cell to meet the specifications of the output system.
e. Automatic Control System - the assembly of sensors, actuators valves, switches, and control logic components that maintains the portable fuel cell power system control parameters within manufacturer specified limits without manual intervention.
f. Fuel Cell Module - an assembly of cells, separators and cooling plates, manifolds and
a supporting structure that electrochemically converts fuel and oxidant to direct electrical current, heat, water and other byproducts.
1.1.5 These requirements are not intended to prevent the design and construction of a portable fuel cell power system not specifically prescribed in this standard, provided that such
alternative has been considered in testing and listing the portable fuel cell power system. In considering alternative designs or construction the materials or methods used shall be
evaluated as to their ability to yield equivalent performance to that prescribed by this standard.

More CSA standard pdf

CSA C22.2 NO. 60601-2-65A:15 (R2020)

CSA C22.2 NO. 60601-2-65A:15 (R2020)

Amendment 1:2019 (IDT) to CAN/CSA-C22.2 No. 60601-2-65:15 Medical electrical equipment - Part 2-65: Particular requirements for the basic safety and essential performance of dental intra-oral X-ray equipment (IEC 60601-2-65:2012, MOD)

$12.00 $25.00

CSA C22.2 NO. 60601-2-63A:15 (R2020)

CSA C22.2 NO. 60601-2-63A:15 (R2020)

Amendment 1:2019 (IDT) to CAN/CSA-C22.2 No. 60601-2-63:15 Medical electrical equipment ? Part 2-63: Particular requirements for the basic safety and essential performance of dental extra-oral X-ray equipment (IEC 60601-2-63:2012, MOD)

$12.00 $25.00

CSA Z259.18:19

CSA Z259.18:19

Counterweighted guardrail systems

$60.00 $120.00

CSA Z45001:19

CSA Z45001:19

Occupational health and safety management systems - Requirements with guidance for use

$104.00 $209.00