• CSA C22.2 NO. 13-1962 (R2011)

CSA C22.2 NO. 13-1962 (R2011)

Transformers for Luminous-Tube Signs, Oil- or Gas-Burner Ignition Equipment, Cold-Cathode Interior Lighting

CSA Group, 01/17/2000

Publisher: CSA

File Format: PDF

$44.00$88.00


Published:17/01/2000

Pages:47

File Size:1 file , 840 KB

Note:This product is unavailable in Russia, Ukraine, Belarus

1. Scope

Section A - Transformers for Luminous-Tube Signs

A1.1

This section applies to transformers for luminous-tube signs of portable and stationary types, for potentials up to and includ ing 600 volts low-potential, and l5,000 volts open-circuit high-potential, designed to be employed in accordance with the rules of the Canadian Electrical Code, Part I.

It includes: (a) outdoor types - Enclosed , non-weatherproof construction intended for use within the enclosures of signs; (b) indoor types:,, (i) enclosed , including pendent-type transformers (and ""standing-type"" transformers); and,, (ii) open or skeleton-type transformers; and (c) reactors, if supplied as part of a transformer. Having sealed-in (ie, compound-sealed) windings.

A1.2

Transformers covered by this Section for use as auxiliary equ ipment for signs used for general advertising and display purposes. /

Section B - Transformers for Oil- or Gas-Burner Ignition Equipment

B1.1

This Section applies to transformers for oil- and gas- burner ignition equipment for potentials up to and including 600 volts low-potential, and 15,000 volts open-circuit high- potential, designed to be employed in accordance with the rules of t he Canadian Electrical Code, Part I. Note: The terms ""low-potential"" and ""high-potential"" are used herein, respectively, for ""primary"" or ""low-voltage"", and ""secondary"" or ""high-voltage"".

B1.2

Transformers covered by this Section are intended for use as auxiliary equipment for oil- and gas-burning apparatus. /

Section C - Transformers for Cold-Cathode Interior Lighting

C1.1

This Section applies to transformers for cold-cathode, high-voltage, luminous tubing, for potentials up to and including 600 volts low-potential and 15,000 volts open-circuit high-potential, designed to be employed in accordance with the rules of the Canadian Electrical Code, Part I. Note: The terms ""low-potential"" and ""high-potential"" are used herein for ""primary"" or ""low-voltage"" and ""secondary"" or ""high- voltage"" respectively.

It includes: (a) (i) Enclosed transformers having sealed-in windings; and (ii) Open or skeleton-type transformers; and (b) Reactors, if supplied as part of a transformer.

C1.2

It does not apply to transformers for lighting systems under 1,0 00 volts.

C1.3

Transformers covered by this Specification are intended for use as auxiliary equipment for interior lighting.

More CSA standard pdf

CSA B149.5-10 (R2014)

CSA B149.5-10 (R2014)

Installation code for propane fuel systems and tanks on highway vehicles

$52.00 $105.00

CSA A660-10 (R2019)

CSA A660-10 (R2019)

Certification of Manufacturers of Steel Building Systems, Includes Update No. 1 (2010)

$44.00 $88.00

CSA ANSI/CSA/IGSHPA C448 Series-16 (R2021)

CSA ANSI/CSA/IGSHPA C448 Series-16 (R2021)

Design and installation of ground source heat pump systems for commercial and residential buildings

$77.00 $155.00

CSA ANSI Z21.13-2010/CSA 4.9-2010

CSA ANSI Z21.13-2010/CSA 4.9-2010

Gas-Fired Low Pressure Steam and Hot Water Boilers

$410.00 $820.00