• CSA C22.2 NO. 198.1-99 (R2004)

CSA C22.2 NO. 198.1-99 (R2004)

Extruded Insulating Tubing (Bi-national standard, with UL 244)

CSA Group, 04/02/2000

Publisher: CSA

File Format: PDF

$144.00$289.00


Published:02/04/2000

Pages:74

File Size:1 file , 1.2 MB

Note:This product is unavailable in Russia, Ukraine, Belarus

1. Scope

1.1

This Standard specifies the requirements for insulating tubing that is usually round in cross-section and that consists entirely of extruded compounds whose characteristic constituents are thermosetting, elastomeric, or thermoplastic polymers (see Table 1 for materials and ratings). These requirements also cover heat-shrinkable and crosslinked tubing.

1.2

Tubing is intended for use only in air - in dry and damp locations - as part of the internal wiring of electrical devices and appliances in accordance with the Canadian Electrical Code, Part 1 (CE Code, Part 1) and the ANSI/NFPA 70 National Electrical Code (NEC). It may be used for insulating one or more inadequately insulated conductors, bus bars, motor leads, transformer leads, terminal lugs, or small assemblies of electronic components. Tubing is not acceptable for use in contact with sharp edges, corners, or projections, or where subject to tension, compression, or repeated flexing. Tubing is not for use where it is feasible to employ a standard insulated conductor (appliance-wiring material) intended specifically for the purpose.

1.3

These requirements do not apply to fabric tubing, polymeric tubing extruded with reinforcement, or tubing intended only for mechanical protection (unless additional tests are conducted).

1.4

These requirements do not apply to chemically dilated tubing.

1.5

The acceptability of tubing in any particular device or appliance depends upon its acceptability for continued use under the conditions that prevail in actual service. Accordingly, for a particular application, tubing device, or appliance in question, it may be necessary to employ tubing having features other than or in addition to those specified in these requirements. For example, tubing may be required to have a heavier wall thickness or a flat rather than a round cross- section; it may be required to have inherent resistance to the effects of immersion in water, oil, solvents, or other liquids (or their vapours); it may be required to be for use in an environment conducive to the development of fungi and similar organisms.

More CSA standard pdf

CSA N285.5-18

CSA N285.5-18

Periodic Inspection of CANDU Nuclear Power Plant Containment Components

$995.00 $1,990.00

CSA 2.33:19/ANSI Z21.88:19

CSA 2.33:19/ANSI Z21.88:19

Vented gas fireplace heaters, Includes Errata (2021)

$419.00 $838.00

CSA Z245.30-18

CSA Z245.30-18

Field-applied external coatings for steel pipeline systems, Includes Update No. 1 (2019)

$127.00 $255.00

CSA C22.1CIICHB-18

CSA C22.1CIICHB-18

Commercial, Industrial & Institutional Construction Handbook - 2018 Canadian Electrical Code

$57.00 $115.00