CSA C22.2 NO. 5-13

Molded-case circuit breakers, molded-case switches and circuit-breaker enclosures (Tri-national standard, with UL 489 and NMX-J-266-ANCE-2013), Update No. 1 (2014)

CSA Group, 01/15/2013

Publisher: CSA

File Format: PDF

$435.00$870.00


Published:15/01/2013

Pages:262

File Size:1 file , 3.6 MB

Note:This product is unavailable in Russia, Ukraine, Belarus

Preface

This is the harmonized ANCE, CSA Group, and UL Standard for Molded-Case Circuit Breakers, Molded-Case Switches, and Circuit-Breaker Enclosures. It is the fourth edition of NMX-J-266-ANCE, the third edition of CSA C22.2 No. 5, and the twelfth edition of UL 489. This edition of CSA C22.2 No. 5 supersedes the previous edition published in 2009. This harmonized standard has been jointly revised on January 15, 2013. For this purpose, ANCE, CSA and UL are issuing a new edition dated January 15, 2013.

Scope

1.1 The requirements of this standard cover molded-case circuit breakers, circuit breaker and ground-fault circuit-interrupters, fused circuit breakers, high-fault protectors, and high-fault modules. These circuit breakers are specifically intended to provide service entrance, feeder, and branch circuit protection in accordance with the National Installation Codes in Annex B, Ref. No.1. This standard also covers instantaneous-trip circuit breakers (circuit interrupters) specifically intended for use as part of a combination motor controller in accordance with the National Installation Codes in Annex B, Ref. No. 1.

1.2 This standard covers molded-case switches and fused molded-case switches.

1.3 This standard covers devices rated at 600 volts or less and 6000 amperes or less.

1.4 The devices referenced in 1.1 and 1.2 are intended for installation in an overall enclosure or as parts of other devices such as panelboards. The acceptability of the combination will be determined when the complete product is investigated.

1.5 This standard covers circuit-breaker enclosures and accessory devices intended for use with the devices described in 1.1 and 1.2.

1.6 This standard does not cover low-voltage power circuit breakers covered in Annex B, Ref. No. 3 and Ref. No. 4 or supplementary protectors covered in Annex B, Ref. No. 5.

1.7 This standard contains supplements covering the requirements for molded-case circuit breakers for:

  1. Marine Use;
  2. Naval Use;
  3. Uninterruptible Power Supply Use;
  4. Classified Circuit Breakers; and
  5. Software in Programmable Components.

More CSA standard pdf

CSA C22.1HB-12

CSA C22.1HB-12

CE code handbook, an explanation of rules of the canadian electrical code, part 1

$65.00 $130.00

CSA Z783-12 (R2021)

CSA Z783-12 (R2021)

Deconstruction of buildings and their related parts

$46.00 $93.00

CSA Z1004-12 (R2021)

CSA Z1004-12 (R2021)

Workplace ergonomics - A management and implementation standard

$81.00 $163.00

CSA Z275.4-12 (R2017)

CSA Z275.4-12 (R2017)

Competency Standard for Diving, Hyperbaric Chamber, and Remotely Operated Vehicle Operations, Includes Update No. 1 (2012)

$56.00 $113.00