CSA W203:19

Planning, design, operation, and maintenance of wastewater treatment in northern communities using lagoon and wetland systems

CSA Group, 06/01/2019

Publisher: CSA

File Format: PDF

$37.00$75.00


Published:01/06/2019

Pages:72

File Size:1 file , 5.9 MB

Note:This product is unavailable in Russia, Ukraine, Belarus

1.1 Scope
This Standard specifically addresses the planning, design, operation, and maintenance of intermittent/seasonal discharge lagoon and wetland systems that are most appropriate for use in Northern regions, where effluent discharge is either difficult or not possible in colder months.

1.2 Application
In this Standard, the North is considered above the 54th parallel. It can also apply in communities where the same challenges, such as extreme climatic conditions and remoteness, appear. This Standard applies across Northern Canada to all municipal wastewater lagoons and wetlands used for the treatment of municipal wastewater from
a) cities, towns, villages, hamlets, settlements, community governments, and unorganized communities; and
b) any site deemed in the public?s interest by a regulatory authority. WTAs should only be considered in remote northern environments where costs and feasibility are prohibitive for the use of constructed wetlands.

1.3 Exclusions
This Standard does not address mechanical aeration of lagoon systems, natural lakes, and exfiltration lagoons.

1.4 Terminology
In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; "may" is used to express an option or that which is permissible within the limits of the standard; and "can" is used to express possibility or capability.

Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

More CSA standard pdf

CSA C22.2 NO. 5-09

CSA C22.2 NO. 5-09

Molded-case circuit breakers, molded-case switches and circuit-breaker enclosures (Tri-national standard, with UL 489 and NMX-J-266-ANCE-2010), Includes Update No. 1 (2011)

$553.00 $1,107.00

CSA C22.2 NO. 35-09 (R2019)

CSA C22.2 NO. 35-09 (R2019)

Extra-low-voltage control circuit cable, low-energy control cable, and extra-low-voltage control cable, Includes Update No. 1 (2010), Update No. 2 (2014)

$112.00 $225.00

CSA ANSI Z21.10.1a-2009/CSA 4.1a-2009

CSA ANSI Z21.10.1a-2009/CSA 4.1a-2009

Addenda 1 to ANSI Z21.10.1-2009/CSA 4.1-2009, Gas water heaters - Volume I, storage water heaters with input ratings Of 75,000 Btu per hour or less

$55.00 $111.00

CSA ANSI Z83.7b-2009/CSA 2.14b-2009

CSA ANSI Z83.7b-2009/CSA 2.14b-2009

Addenda 2 to ANSI Z83.7-2000/CSA 2.14-2000, Gas-Fired Construction Heaters

$40.00 $81.00