• CSA Z107.52-M1983 (R2004)

CSA Z107.52-M1983 (R2004)

Recommended Practice for the Prediction of Sound Pressure Levels in Large Rooms Containing Sound Sources

CSA Group, 05/04/2000

Publisher: CSA

File Format: PDF

$109.00$218.38


Published:04/05/2000

Pages:22

1. Scope

1.1

This Recommended Practice describes a procedure for the prediction of sound pressure levels in a large room containing a number of sound sources. This procedure may be used to compute A-weighted, octave, or fractional octave band sound pressure levels over continuous contours, or at specific points, to predict:

(a) Sound pressure levels at the design stage;

(b) The effect of altering or moving equipment in an existing space; and

(c) The effect of changing the acoustical environment.

1.2

The use of the procedure described in this Recommended Practice requires that the sound emitted from each source (preferably measured in accordance with CSA Standard Z107.51, Procedure for In-Situ Measurement of Noise From Industrial Equipment) be known. When this procedure is used to predict the effect of installing or removing one or more machines, it is sufficient to know the sound pressure levels in the existing space, as well as the sound power levels of each machine.

1.3

This Recommended Practice applies to rectangular rooms with a relatively constant height. The length and width of the room should each be greater than about 4 times the height. Where the roo m geometry departs materially from the simple rectangular shape, the prediction given by this procedure may be incorrect.

1.4

This Recommended Practice can be used with the knowledge of the length of time spent by workers at various locations to estimate the ir sound exposure.

1.5

This Recommended Practice does not apply to:

(a) The prediction of the sound pressure levels resulting from the introduction of large sources, objectives, or barriers at distances less than four times their largest dimension;

(b) The prediction of impulse sound levels;

(c) The prediction of sound pressure levels if a highly directive noise source is added; and

(d) The prediction of sound pressure levels if a noise source has a predominate pure tone.

More CSA standard pdf

CSA S505:20

CSA S505:20

Techniques for considering high winds and snow drifting and their impact on northern infrastructure

$62.00 $125.00

CSA Z460:20

CSA Z460:20

Control of hazardous energy - Lockout and other methods

$74.00 $149.00

CSA ANSI Z21.91:20

CSA ANSI Z21.91:20

Ventless firebox enclosures for gas-fired unvented gas log type room heaters

$295.00 $590.00

CSA C68.5:20

CSA C68.5:20

Primary shielded and concentric neutral cable for distribution utilities, Include Update No. 1 (2023)

$119.00 $238.00