• CSA Z343-98 (R2002)

CSA Z343-98 (R2002)

Test Methods for In-Line and Firebox Flame Arresters

CSA Group, 04/01/1998

Publisher: CSA

File Format: PDF

$29.00$58.00


Published:01/04/1998

Pages:48

File Size:1 file , 970 KB

Note:This product is unavailable in Russia, Ukraine, Belarus


1. Scope
1.1 This Standard describes test methods for use in assessing the performance of porous media element flame arresters intended for use with Class I, Group C and D flammable gases and vapours, as defined in CSA Standard C22.1 in applications such as flare stacks, firebox air intakes, and vent lines. This Standard does n ot apply to the details of construction, specification, selection, application, maintenance, or any of the other factors that must be considered for a suitable flame arrester installation. Notes: (1) See Appendix A for general background information concerning flame arresters and test procedures. (2) With the exception of the terms ""flame arrester"", ""firebox"", and ""in-line flame arrester"", terms that are defined in Clause 3 are shown in italics in the text elsewhere throughout this Standard.
1.2 This Standard applies to flame arrester installations where the ambient temperature to which the arrester is exposed is in the range -45 to 100?C, and where the maximum operating pressure for flame arrestment is 108.25 kPa (absolute), unless otherwise stated by the manufacturer (see Clause 1.4). This Standard covers the testing of complete flame arrester units only (consisting, as a minimum, of a flame arrester housing and flame arrester element), and does not apply to the testing of individual components thereof. Performance tests of a flame suppression system, which may form part of a flame arrester assembly, are not within the scope of this Standard. A flame warning system is mandatory for any in-line flame arrester being tested to this Standard. Notes: (1) The above temperature range is intended to represent normal outdoor seasonal temperature and pressure extremes to which a flame arrester may be exposed in normal use. (2) A device tested to this Standard may be operated at higher pressures, but flame arresting capabilities at pressures above 108.25 kPa (absolute) are not within the scope of this Standard, unless performance claims in this regard are stated by the manufacturer (see Clause 1.4). Internal operating pressures would normally be expected to be lower than 108.25 kPa (absolute) w here a low flow or loss of flo

More CSA standard pdf

CSA C22.2 NO. 184.1:15 (R2020)

CSA C22.2 NO. 184.1:15 (R2020)

Solid-State Dimming Controls (Bi-national standard, with UL 1472), Includes Update No. 1 (2017), Update No. 2 (2020), and Update No. 3 (2022)

$247.00 $495.00

CSA C22.2 No. 60079-31:15 (R2020)

CSA C22.2 No. 60079-31:15 (R2020)

Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t" (Adopted IEC 60079-31:2013, second edition, 2013-11, with Canadian deviations)

$30.00 $60.00

CSA C22.2 NO. 52-15

CSA C22.2 NO. 52-15

Underground secondary and service-entrance cables

$127.00 $254.15

CSA C22.2 NO. 94.2:15 (R2020)

CSA C22.2 NO. 94.2:15 (R2020)

Enclosures for Electrical Equipment, Environmental Considerations (Tri-National Standard, with NMX-J-235/2-ANCE-2007 and UL 50E)

$144.00 $289.00