IEC 60331-1 Ed. 2.0 b:2018

Tests for electric cables under fire conditions - Circuit integrity - Part 1: Test method for fire with shock at a temperature of at least 830 ¿¿C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter exceeding 20 mm

International Electrotechnical Commission, 03/28/2018

Publisher: IEC

File Format: PDF

$117.00$234.00


Published:28/03/2018

Pages:55

File Size:1 file , 1.4 MB

Note:This product is unavailable in Ukraine, Russia, Belarus

IEC 60331-1:2018 specifies the test method for cables which are required to maintain circuit integrity when subject to fire and mechanical shock under specified conditions.
This document is applicable to cables of rated voltage not exceeding 600 V/1 000 V, including those of rated voltage below 80 V, metallic data and telecom cables and optical fibre cables.
It is intended for use when testing cables of greater than 20 mm overall diameter.
Cables of smaller diameter are intended to be tested using the apparatus, procedure and requirements of IEC 60331-2.
This document includes details for the specific point of failure, continuity checking arrangement, test sample, test procedure and test report relevant to electric power and control cables with rated voltage up to and including 600 V/1 000 V. Details for the specific point of failure, continuity checking arrangement, test sample, test procedure and test report relevant to metallic data and telecom cables and optical fibre cables are not given by IEC 60331-1.
Although the scope is restricted to cables with rated voltage up to and including 0,6/1,0 kV, the procedure can be used, with the agreement of the manufacturer and the purchaser, for cables with rated voltage up to and including 1,8/3 (3,3) kV, provided that suitable fuses are used.
Annex A provides the method of verification of the burner and control system used for the test.
Requirements are stated for an identification that may optionally be marked on the cable to signify compliance with this document.
This second edition cancels and replaces the first edition published in 2009. It constitutes a technical revision.
The significant technical changes with respect to the previous edition are as follows:
- extension of the scope to include metallic data and telecom cables and optical fibre cables, although details for the specific point of failure, continuity checking arrangement, test sample, test procedure and test report relevant to metallic data and telecom cables and optical fibre cables are not given by IEC 60331-1;
- improved description of the test environment;
- modified steel test ladder with two extra vertical elements to accommodate the modified testing of single core cables without concentric metal layer and the testing of cables with a bending radius in normal use larger than approximately 400 mm;
- mandatory use of mass flow meters/controllers as the means of controlling accurately the input flow rates of fuel and air to the burner;
- improved description of the information to be included in the test report.

More IEC standard pdf

IEC 60562 Ed. 1.0 b:1976

IEC 60562 Ed. 1.0 b:1976

Measurements of incidental ionizing radiation from electronic tubes

$25.00 $51.00

IEC 60418-4 Ed. 1.0 b:1976

IEC 60418-4 Ed. 1.0 b:1976

Variable capacitors. Part 4: Type specification for variable pre-set capacitors Type C

$23.00 $47.00

IEC 60169-13 Ed. 1.0 b:1976

IEC 60169-13 Ed. 1.0 b:1976

Radio-frequency connectors - Part 13: R.F. coaxial connectors with inner diameter of outer conductor 5.6 mm (0.22 in) - Characteristic impedance 75 ohms (Type 1.6/5.6) - Characteristic impedance 50 ohms (Type 1.8/5.6) with similar mating dimensions

$72.00 $145.00

IEC 60389-1 Amd.1 Ed. 1.0 b:1976

IEC 60389-1 Amd.1 Ed. 1.0 b:1976

Amendment 1 - Thermostatic switches primarily for use in equipment for telecommunications and in electronic applications employing similar techniques. Part 1: General requirements and measuring methods

$8.00 $17.00