IEC 60439-4 Ed. 2.0 b:2004

Low-voltage switchgear and controlgear assemblies - Part 4: Particular requirements for assemblies for construction sites (ACS)

International Electrotechnical Commission, 06/14/2004

Publisher: IEC

File Format: PDF

$58.00$116.00


Published:14/06/2004

Pages:39

File Size:1 file , 830 KB

Note:This product is unavailable in Ukraine, Russia, Belarus

Applies to type-tested ASSEMBLIES (TTA) intended for use on construction sites, i.e. temporary places of work to which the public do not generally have access and where building construction, installation, repairs, alteration or demolition of property (buildings) or civil engineering (public works) or excavation or any other similar operations are carried out. These ASSEMBLIES may be transportable (semi-fixed) or mobile. This standard does not apply to ASSEMBLIES for use in the administrative centres of construction sites (offices, cloakrooms, ASSEMBLY rooms, canteens, restaurants, dormitories, toilets, etc.). The nominal primary voltage and the nominal secondary voltage of transformers incorporated in ACS shall be within the limits specified in IEC 60439-1. Requirements for electrical protection provided by equipment manufactured according to this International Standard shall comply with the requirements given in IEC 60364-7-704. NOTE: This standard may be used as a guide to partially type-tested ASSEMBLIES (PTTA) constructed according to agreement between manufacturer and user taking into account the nature of supply and/or distribution network and relevant installation requirements. The following major changes with respect to edition 1 (including amendments 1 and 2) have been incorporated: - introduction of the definition for ""rated current of ACS""; - replacement of classification based on the rated current of ACS by classification based on the function as assigned by the manufacturer; - amended requirements for the protection of socket-outlets with reference to the more comprehensive requirements of IEC 60364-7-704; - introduction of common requirements for all types of ACS.

More IEC standard pdf

IEC 61300-2-38 Ed. 2.0 b:2006

IEC 61300-2-38 Ed. 2.0 b:2006

Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-38: Tests - Sealing for pressurized fibre optic closures

$12.00 $25.00

IEC 60748-21-1 Ed. 2.0 b:1997

IEC 60748-21-1 Ed. 2.0 b:1997

Semiconductor devices - Integrated circuits - Part 21-1: Blank detail specification for film integrated circuits and hybrid film integrated circuits on the basis of qualification approva lprocedures

$47.00 $95.00

IEC 60730-2-2 Amd.1 Ed. 2.0 b:2005

IEC 60730-2-2 Amd.1 Ed. 2.0 b:2005

Amendment 1 - Automatic electrical controls for household and similar use - Part 2-2: Particular requirements for thermal motor protectors

$12.00 $24.00

IEC 60748-22-1 Ed. 2.0 b:1997

IEC 60748-22-1 Ed. 2.0 b:1997

Semiconductor devices - Integrated circuits - Part 22-1: Blank detail specification for film integrated circuits and hybrid film integrated circuits on the basis of the capability approval procedures

$47.00 $95.00