• IEC 60800 Ed. 3.0 b:2009

IEC 60800 Ed. 3.0 b:2009

Heating cables with a rated voltage of 300/500 V for comfort heating and prevention of ice formation

International Electrotechnical Commission, 07/23/2009

Publisher: IEC

File Format: PDF

$110.00$221.00


Published:23/07/2009

Pages:58

File Size:1 file , 1 MB

Note:This product is unavailable in Ukraine, Russia, Belarus

IEC 60800:2009 is applicable to, and specifies requirements for, resistive heating cables for low temperature applications such as comfort heating and the prevention of ice formation. These cables and cable sets may comprise either factory fabricated or field (work-site) assembled units, and which are heating cables assembled in accordance with manufacturer's instructions. Bare conductors and protected conductors to be supplied at voltages equal to, or less than, 50 V are excluded from the scope of this standard. Typical applications include, but are not limited to
- surface heating installed in or under surfaces
- direct and storage heating
- snow melting and frost protection of roofs, gutters, pipes, etc.
Heating cables for industrial and commercial applications are specified in the IEC 62395 series as are mineral insulated heating cables. Applications in which the operating sheath temperature exceeds 100 °C are outside the scope of this standard. The object of this standard is to ensure that electrical resistance heating cables operate safely under their normal defined conditions of use. This is achieved by:
- employing heating cables of the appropriate construction that meet the test criteria detailed in this standard
- including, for cables with an electrical protective component, a metallic braid, concentric wires or sheath, or other suitable electrically conductive material for protective purposes in case of fault
- ensuring that the cables operate at safe temperatures with respect to the materials used in the construction of the cables and their installations according to national regulations.
The significant technical changes with respect to the previous edition are as follows
- introduction of heating cable sets
- testing of heating cable sets, including the integrated cold-lead, cold-lead splice and end-termination in twin and multicore cable sets, in addition to the heating cable
- introduction of requirements for installation instructions
- reduction to two, instead of three, mechanical classes, one for cables intended for installation with a low risk of mechanical damage (M1) and one for cables intended for installation with a higher risk of mechanical damage (M2)
- elimination of reference to specific materials to be used as insulation and sheath
- introduction of routine and sample tests.

More IEC standard pdf

IEC 60454-3-11 Ed. 1.0 b:1998

IEC 60454-3-11 Ed. 1.0 b:1998

Pressure-sensitive adhesive tapes for electrical purposes - Part 3: Specifications for individual materials - Sheet 11: Combination tapes made of creped cellulosic paper and polyethylene terephthalate film with rubber thermosetting adhesive

$12.00 $25.00

IEC 62255-3-1 Ed. 1.0 b:2006

IEC 62255-3-1 Ed. 1.0 b:2006

Multicore and symmetrical pair/quad cables for broadband digital communications (high bit rate digital access telecommunication networks) - Outside plant cables - Part 3-1: Filled cables - Blank detail specification

$23.00 $46.00

IEC 60601-2-24 Ed. 1.0 en:1998

IEC 60601-2-24 Ed. 1.0 en:1998

Medical electrical equipment - Part 2-24: Particular requirements for the safety of infusion pumps and controllers

$140.00 $281.00

IEC 60287-2-1 Amd.1 Ed. 1.0 b:2001

IEC 60287-2-1 Amd.1 Ed. 1.0 b:2001

Amendment 1 - Electric cables - Calculation of the current rating - Part 2: Thermal resistance - Section 1: Calculation of thermal resistance

$8.00 $17.00